OKOS 2 Gang 16A Zigbee Smart Switch Module | Gateway Required
Before you buy Lighting on/off control only. For compatible lighting circuits only, with on/off switching. Do not connect heavy-load appliances or inductive/motor loads such as fans or pumps. This is not a dimmer or fan-speed controller. LED-driver compatibility, startup/inrush current and the permitted lighting load must be checked for this exact model before installation; an amp marking is not a universal LED wattage allowance. Compatible Zigbee gateway required. A compatible Zigbee gateway is mandatory for OKOS Smart app control and connected smart functions. The gateway is a separate device in the system: this module does not connect directly to a Wi-Fi router. Confirm gateway compatibility and what is included in your purchase before ordering. OKOS • Retrofit lighting control Your familiar switches. Now connected. Add independent on/off control to 2 lighting circuits with the OKOS 2-gang Zigbee smart switch module. Keep local wall-switch operation and bring compatible lighting into your connected home. Zigbee 3.0Gateway requiredNeutral required AI-assisted cleaned product image based on the supplied Zigbee unit photograph. Product illustration only, not a wiring guide. Thoughtfully connected Keep the control that suits your day 2 independent circuitsSwitch each connected lighting circuit on or off separately. Familiar wall controlsExternal switch inputs let you retain local control after professional installation. App-connected lightingUse Smart Life or OKOS Smart through a compatible Zigbee gateway. The right connection Zigbee module → compatible gateway → your app This listing is for the Zigbee version, not Wi-Fi. The module does not pair directly with a Wi-Fi router. Your gateway provides the compatible connection to Smart Life or OKOS Smart. A compatible Zigbee gateway is mandatory for OKOS Smart app control and connected smart functions. The gateway is a separate device in the system: this module does not connect directly to a Wi-Fi router. Confirm gateway compatibility and what is included in your purchase before ordering. Lighting-load restrictions. Use a qualified electrician and confirm the exact unit’s permitted lighting load before installation. Choose the load carefully Designed around the right lighting circuit For compatible lighting circuits only, with on/off switching. Do not connect heavy-load appliances or inductive/motor loads such as fans or pumps. This is not a dimmer or fan-speed controller. LED-driver compatibility, startup/inrush current and the permitted lighting load must be checked for this exact model before installation; an amp marking is not a universal LED wattage allowance. Important rating noteThe specified channel rating is 16 A per channel. The product label also marks input and output 16 A max. The per-channel specification is not a tested LED wattage limit or permission to apply that current to every output simultaneously. Confirm the permitted lighting load, LED-driver startup/inrush current and combined limit for this exact model; do not multiply the channel rating into a total load. Relay amperage is not an LED wattage rating. At a glance Technical specifications Channels 2 independent on/off circuits Wireless protocol Zigbee 3.0 — not a direct Wi-Fi module Gateway Compatible Tuya/OKOS Zigbee gateway required for app control Apps Smart Life (Tuya) or OKOS Smart App, through a compatible gateway Input / output voltage 100–240V AC, 50/60Hz Channel specification and label limits The specified channel rating is 16 A per channel. The product label also marks input and output 16 A max. The per-channel specification is not a tested LED wattage limit or permission to apply that current to every output simultaneously. Confirm the permitted lighting load, LED-driver startup/inrush current and combined limit for this exact model; do not multiply the channel rating into a total load. Neutral wire Required, together with live supply Local control Connections for 2 external wall-switch inputs Function On/off switching; not a dimmer or fan-speed controller Warranty 1 year Before you fit it Plan. Install. Test. 1 · Confirm suitabilityCheck the gateway, neutral, enclosure space and permitted channel and total loads. 2 · Use an electricianIsolate and prove the supply dead. Follow the exact unit’s supplied wiring instructions. 3 · Commission every circuitPair through the compatible gateway. Name each circuit and test local and app control. Good to know Frequently asked questions Do I need a Zigbee gateway, or can I connect directly to Wi-Fi?A compatible Zigbee gateway is mandatory for OKOS Smart app control and connected smart functions. The gateway is a separate device in the system: this module does not connect directly to a Wi-Fi router. Confirm gateway compatibility and what is included in your purchase before ordering.Can I keep using my wall switches?Yes. The module has connections for 2 external wall-switch inputs. A qualified electrician must follow the wiring instructions supplied with the exact unit.Is a neutral wire needed?Yes. This model requires live and neutral at the installation point. It is not a no-neutral module.How much load can I connect?The specified channel rating is 16 A per channel. The product label also marks input and output 16 A max. The per-channel specification is not a tested LED wattage limit or permission to apply that current to every output simultaneously. Confirm the permitted lighting load, LED-driver startup/inrush current and combined limit for this exact model; do not multiply the channel rating into a total load. LED-driver inrush current and load type can reduce the permitted working load. Confirm the total simultaneous load with OKOS before installation.Which loads can I connect? Can it dim lights or control appliances?For compatible lighting circuits only, with on/off switching. Do not connect heavy-load appliances or inductive/motor loads such as fans or pumps. This is not a dimmer or fan-speed controller. LED-driver compatibility, startup/inrush current and the permitted lighting load must be checked for this exact model before installation; an amp marking is not a universal LED wattage allowance.What should I check before installation?Check gateway compatibility, neutral availability, enclosure space and load suitability. A qualified electrician should isolate and prove the supply dead before wiring; app OFF is not electrical isolation.What affects response time?Response varies with radio signal, router or gateway connection, internet/cloud services when used, and LED-driver start-up. Wall-switch and app commands use different paths. No fixed millisecond delay or zero-delay guarantee is specified for these modules.Does app OFF isolate power, and does the wall switch bypass the module?App OFF is a control command, not electrical isolation. The wall switch connects to the module's control inputs; it must not be treated as an independent fail-safe mechanical bypass. For electrical work, isolate the circuit at the appropriate isolating device and have a qualified electrician verify absence of voltage. Smart control behind familiar switches Illustrative Indian six-module switchboard layout, not to scale and not a wiring guide. The rocker count does not represent the module channel count. A qualified electrician must check actual box clearance, neutral availability, switch compatibility and wiring for the supplied unit. A compatible Zigbee gateway is required for app control.Practical installation and everyday use Review the connection requirements and lighting restrictions before ordering. Exact dimensions and permitted LED-driver loads must be confirmed for the supplied model. What affects response time? Response varies with radio signal, router or gateway connection, internet/cloud services when used, and LED-driver start-up. Wall-switch and app commands use different paths. No fixed millisecond delay, zero-delay performance, or guaranteed offline behavior is promised.Choose the right channel count 1, 2, 3 and 4 gang mean that many separately switched lighting channels, not pack quantity. More channels do not establish a safe combined load. Every connected lighting group must meet the exact model's verified limits.2-gang lighting wiring reference 2-gang source-label load wiring reference: supply live to terminal 3 L-in and neutral to terminal 4 N-in; light 1 live to terminal 1 L1, light 2 live to terminal 2 L2; both light neutrals to supply neutral. Match the exact label. Qualified electrician only; isolate and verify absence of voltage. Diagram orientation is label upright, terminals left to right. Dots indicate joined conductors; bridges indicate crossings without connection. Colors show function, not installed wire colors. Connection reference only: protective earthing, circuit protection and enclosure wiring are not shown. These must be retained or provided as required for the installation. Isolate the supply and verify absence of voltage; installation by a qualified electrician. Match the exact supplied label.2-gang optional wall-switch wiring 2-gang source-label optional wall-switch wiring: switch 1 between terminal 6 S1 and terminal 4 N-in; switch 2 between terminal 5 S2 and terminal 4 N-in. Do not connect switch inputs to live. Match the exact supplied label; qualified electrician only. Diagram orientation is label upright, terminals left to right. Dots indicate joined conductors; bridges indicate crossings without connection. Colors show function, not installed wire colors. Connection reference only: protective earthing, circuit protection and enclosure wiring are not shown. These must be retained or provided as required for the installation. Isolate the supply and verify absence of voltage; installation by a qualified electrician. Match the exact supplied label.2-gang load-terminal reference 2-gang numbered terminal reference, label upright, left to right. Supply live: terminal 3 L-in; neutral: terminal 4 N-in. Light 1 live: terminal 1 L1; light 2 live: terminal 2 L2. Both light neutrals connect to supply neutral. Exact supplied label must match; qualified electrician only.2-gang optional wall-switch reference 2-gang optional wall switches: switch 1 between terminal 6 S1 and terminal 4 N-in; switch 2 between terminal 5 S2 and terminal 4 N-in. Never connect S1 or S2 to live. Match the exact unit label; qualified electrician installation only.
Variants (1)
- Default Title — 1300.00 INR — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.