Hankison VNCA75-FP Non-Cycling Refrigerated Air Dryer – 75 SCFM, 115V/1Ph with Pre & Post Filtration
Hankison VNCA75-FP Non-Cycling Refrigerated Air Dryer – 75 SCFM, 115V/1Ph with Pre & Post Filtration Reliable Compressed Air Drying with Complete Pre & Post Filtration The Hankison VNCA75-FP Non-Cycling Refrigerated Air Dryer provides dependable moisture removal and filtration for compressed air systems requiring up to 75 SCFM of treated air. Designed for industrial shops, manufacturing equipment, pneumatic tools, and other compressed air applications, the VNCA75-FP combines refrigerated air drying with matched Hankison pre and post filtration in one complete air treatment package. Operating on convenient 115V single-phase power, the VNCA75-FP uses R513A low-GWP refrigerant and consumes just 0.51 kW at full rated capacity. Its compact footprint makes it easy to incorporate into compressor rooms, maintenance areas, and industrial compressed air systems where reliable moisture control is required. The VNCA75-FP includes a Hankison F07-PF-DP1 prefilter and F07-HF-DP1 afterfilter, providing filtration before and after the refrigerated dryer for cleaner, drier compressed air throughout your system. Key Features & Benefits 75 SCFM Rated Capacity Rated for 75 SCFM Designed for small to medium industrial compressed air systems Helps remove moisture before it reaches downstream piping and equipment Rated in accordance with ISO 7183 Option A2 conditions Complete Pre & Post Filtration Package Pre and post filtration included Prefilter: F07-PF-DP1 Afterfilter: F07-HF-DP1 Prefiltration helps protect the dryer from incoming contaminants Afterfiltration provides additional compressed air treatment downstream Complete dryer and filtration package eliminates the need to separately select matching filters Non-Cycling Refrigerated Dryer Design Proven non-cycling refrigerated drying technology Provides continuous moisture removal during operation Helps reduce water-related problems in compressed air piping Simple, dependable design for industrial applications R513A Refrigerant Uses modern R513A refrigerant Low-GWP refrigerant designed for improved environmental sustainability Provides efficient refrigerated dryer performance Low Power Consumption Consumes only 0.51 kW Provides effective compressed air drying with low electrical demand Designed for efficient operation at full rated capacity 115V Single-Phase Power 115V / 1Ph / 60 Hz No three-phase electrical service required Convenient for shops, maintenance departments, and industrial facilities Compact Industrial Design 21.0" W x 22.6" D x 25.0" H Approximately 87 lbs. Compact footprint allows flexible installation 3/4" female NPT inlet and outlet connections Condensate Removal Condensate drain furnished with the dryer Removes moisture collected during the refrigeration process Helps maintain dependable dryer operation UL & CSA Certified Third-party certified to applicable UL and CSA standards Designed for safe operation in the United States and Canada Ideal Applications The Hankison VNCA75-FP is ideal for: Automotive repair and service shops Machine shops CNC equipment Woodworking and cabinet shops Light manufacturing Pneumatic tools Pneumatic controls and actuators Maintenance departments Packaging equipment Rotary screw compressor systems Reciprocating air compressor systems General industrial compressed air Technical Specifications Specification Hankison VNCA75-FP Rated Air Flow 75 SCFM Metric Air Flow 127 Nm³/H Dryer Type Non-Cycling Refrigerated Voltage 115V / 1Ph / 60 Hz Power Consumption 0.51 kW Refrigerant R513A Air Inlet / Outlet 3/4" Female NPT Condensate Drain Connection 1/8" FNPT Width 21.0" Depth 22.6" Height 25.0" Shipping Weight 87 lbs. Prefilter F07-PF-DP1 Afterfilter F07-HF-DP1 Filtration Pre & Post Filtration Included Frequently Asked Questions How much compressed air can the Hankison VNCA75-FP handle? The Hankison VNCA75-FP is rated for 75 SCFM under ISO 7183 Option A2 rating conditions. Actual dryer capacity can vary depending on operating pressure, compressed air inlet temperature, ambient temperature, and airflow demand. Does the VNCA75-FP include air filters? Yes. The VNCA75-FP includes both a Hankison F07-PF-DP1 prefilter and F07-HF-DP1 afterfilter, providing filtration before and after the refrigerated dryer. Why is pre and post filtration important? The prefilter helps remove contaminants before compressed air enters the dryer, helping protect the dryer and improve overall air treatment. The afterfilter provides additional filtration before compressed air enters the facility's distribution system or downstream equipment. What voltage does the VNCA75-FP require? The VNCA75-FP operates on 115V single-phase, 60 Hz power, making installation convenient in facilities where three-phase electrical service is not available. What size air connections does the VNCA75-FP use? The dryer uses 3/4-inch female NPT inlet and outlet connections. What refrigerant does the Hankison VNCA75 use? The VNCA75 uses R513A refrigerant, the low-GWP refrigerant used throughout the Hankison VNCA Series. What are the rated conditions for the VNCA75-FP? Hankison rates the VNCA Series in accordance with ISO 7183 Option A2 at: 100 PSIG inlet pressure 100°F compressed air inlet temperature 100°F ambient temperature 60 Hz electrical supply Does the VNCA75-FP include a condensate drain? Yes. Hankison VNCA Series dryers are furnished with condensate drains for efficient condensate removal.
Variants (1)
- Default Title — 2484.00 USD — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.