APsmart Transmitter-PLC Outdoor Kit, Single Core, 85–264VAC Power Supply – 408006
Product Overview The APsmart 408006 is the Single Core Transmitter-PLC Outdoor Kit with an 85–264 VAC power supply. APsmart says the kit includes a Transmitter-PLC with one core, an outdoor enclosure and the power supply. While powered, the Transmitter-PLC sends a signal to APsmart RSD units that keeps their PV modules connected. When the transmitter is switched off, the RSD units enter rapid shutdown, and they resume when power returns. APsmart's Outdoor Kit datasheet says the kit meets NEC 2017, 2020&2023 (690.12) requirements and SunSpec requirements. Best For APsmart RSD-S-PLC systems that need an external transmitter: Where the inverter does not include an integrated SunSpec-certified transmitter. Residential sites with an 85–264 VAC supply: APsmart lists this supply as its residential option. Single core. Key Features & Specifications Specification Details Product type PLC rapid shutdown transmitter outdoor kit, single core Part number (per APsmart) 408006: Single Core Transmitter-PLC Outdoor Kit, 85-264VAC Power Supply Transmitter input (per APsmart) 12 VDC; 0.8 A Power supply (per APsmart) 85–264 VAC input, 12 VDC output; 90 × 17.5 × 58.4 mm Core (per APsmart) ~29 mm wire opening / 65 mm outside; 1500 VDC maximum system voltage Strings per core, without connector (per APsmart) Cable Φ5.9 mm: ≤15; Φ6.35 mm: ≤15; Φ7 mm: ≤14; Φ8.6 mm: ≤10 Maximum string length (per APsmart) 30 modules Maximum cable length, inverter (+) to inverter (−) (per APsmart manual) 1500 ft (450 m) Kit temperature (per APsmart) −40°C to +60°C Kit dimensions (per APsmart) 198.5 × 298 × 179 mm (W × H × D) NEC 690.12 (per APsmart) Meets NEC 2017, 2020&2023 (690.12) requirements Warranty (per APsystems) 3 years from the warranty start date, when used with APsystems Rapid Shutdown Devices Source APsmart Transmitter-PLC Outdoor Kit Datasheet NA Rev 2.8; APsmart RSD-S-PLC / Transmitter User Manual NA Rev 4.4; APsmart Transmitter-PLC Outdoor Kit QIG Rev 2.4 NA; APsystems Limited Warranty for Rapid Shutdown Devices & Transmitter, US L3.1 What You May Also Need Usually required APsmart RSD units on the modules: See the APsmart RSD-S-PLC. An 85–264 VAC supply on the inverter's AC branch circuit. May be required Rapid shutdown labels: APsmart says to place the rapid shutdown system label within 1 m (3 ft) of the Transmitter-PLC or AC disconnect. See PV Labels 05-523 (2023 NEC). Conduit fittings: APsmart says the enclosure is not punched before delivery. The manual gives drilling guides for 3/4" and 1" conduit. Optional upgrades Other rapid shutdown parts: See rapid shutdown. Check current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware. Important Considerations Same AC branch circuit. APsmart's user manual says the power supply of the Transmitter-PLC and the inverter MUST be on the same AC branch circuit to meet rapid shutdown requirements. Core routing. Pass either both positive or both negative cables through a core, never one of each, and follow the core diagrams in APsmart's current user manual. Install order. APsmart says to install the RSD-S-PLC units before powering the Transmitter-PLC. Inverter list. For inverters with an integrated SunSpec-certified transmitter, check the APsmart Compatible Inverters list (apsmartglobal.com), viewed Oct 8, 2026; no revision number. Inverter pairing. Do not assume a specific string inverter, hybrid inverter or microinverter model is listed. Check the maker's current certified list and the document revision or view date before design.
Variants (1)
- Default Title — 250.53 USD — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.