TEXONIC PA260 260W 2-Zone Commercial Mixer Amplifier with Bluetooth & Paging

TEXONIC PA260 260W 2-Zone Commercial Mixer Amplifier with Bluetooth & Paging

Brand: TEXONIC
SKU: PA260
511.00 USD In stock Buy at Merchant

260W COMMERCIAL AUDIO | TWO-ZONE MUSIC & PAGING TEXONIC PA260 2-Zone Commercial Mixer Amplifier The TEXONIC PA260 is a 260W commercial mixer amplifier that brings music playback, microphone announcements and two-area speaker control into one central audio unit. Designed for 100V distributed speaker installations, the PA260 provides two selectable speaker zones so businesses can direct background music and paging to the areas where sound is needed. Built-in Bluetooth, FM radio, USB and SD playback offer convenient music sources. Four microphone channels, two auxiliary inputs and MIC1 voice-priority paging provide flexibility for daily communication and audio playback. With a separate 4–16Ω output option, tone adjustment, microphone echo control and line-level outputs, the PA260 can be integrated into a variety of properly designed commercial speaker systems. 260W Rated Output 2 Selectable Zones 100V Commercial Audio Bluetooth / FM / USB / SD MIC1 Priority Paging Overview Features Specs Zones & Load What's Included Manual Flexible Background Audio for Two Connected Areas The PA260 provides one central location for managing music and routine announcements in two separate speaker areas. Instead of requiring two independent amplifiers, compatible 100V speakers can be organized into two circuits. Front-panel zone switches allow staff to enable Zone 1, Zone 2 or both areas together. The amplifier's music and microphone programme is shared between active zones. This approach is useful for facilities where different parts of a building may not require sound at the same time, but can share one audio source. Where the PA260 Fits Office & Administration Provide background sound in reception and shared workspaces, with paging available through a compatible microphone. Retail & Customer Service Organize speakers between customer-facing areas and staff or support spaces. Community & Training Rooms Use music or announcements in two selectable rooms sharing a central audio system. Hospitality & Recreation Distribute background music through common areas while keeping secondary speaker circuits selectable. Important Zone Distinction: Zone 1 and Zone 2 share the same music and paging programme. The front-panel zone switches provide area selection, not independent music-source routing or separate built-in zone volume controls. Choose Between Built-In and External Audio The PA260 includes Bluetooth and FM radio playback, as well as USB and SD media connections. Two rear AUX inputs are also available for compatible external equipment such as a media streamer, computer audio source or music player. The amplifier can mix compatible microphone and auxiliary signals, allowing background music and routine voice communication to be handled from one unit. Microphone Paging and Announcements Four microphone channels provide connection options for speech, announcements and other suitable microphone applications. MIC1 and MIC2 have convenient front-panel ¼-inch connections. MIC3 and MIC4 use rear-panel combo microphone connections. The MIC1 priority switch can reduce background music during voice announcements, helping the spoken message stand out from the regular audio programme. Line-Level Expansion REC and LINE outputs are provided for connection to compatible external audio equipment. The line output can feed a suitable external power amplifier or active subwoofer when additional audio equipment is required. System Expansion Tip: The LINE connection is a line-level audio signal, not an additional powered speaker output. Compatible Commercial Speakers The PA260 can be used with appropriately configured commercial ceiling speakers and other compatible 100V transformer speakers. For more information on distributed and low impedance speaker systems, read the TEXONIC 70V vs. 8-Ohm Speaker Guide . Key Features 260W rated commercial mixer amplifier Two selectable 100V speaker zones Front-panel Zone 1 and Zone 2 switches Direct 100V speaker output option Separate 4–16Ω low-impedance output Built-in Bluetooth audio playback Integrated FM radio receiver USB and SD media playback MP3 and WMA audio format support Four microphone input channels Front-panel MIC1 and MIC2 ¼-inch inputs Rear MIC3 and MIC4 combo inputs 48V phantom power switch for compatible microphones MIC1 voice-priority ducking function Two external AUX audio inputs Individual MIC1–MIC4 level adjustments Separate AUX1 and AUX2 volume controls Built-in chime function Built-in siren function Adjustable microphone echo control Bass and treble tone adjustments Master output volume control LED audio level meter Front-panel LCD media display Rear REC audio output Line output for compatible external equipment AC 120V, 60Hz operation Microphone Compatibility: The rear-panel MIC3 and MIC4 connections support suitable microphones requiring phantom power. Confirm the microphone's requirements before enabling the 48V switch. Priority Paging The rear-panel MIC1 priority switch enables or disables voice-priority ducking. When enabled, announcements through MIC1 can lower the background music level. This is useful for regular business paging where voice communication must temporarily take precedence. Chime and Siren Controls Dedicated front-panel buttons provide access to the amplifier's built-in chime and siren functions. These functions can be used where appropriate for general-purpose commercial audio announcements. Safety Notice: The presence of a siren function does not establish certification as a regulated fire-alarm or emergency voice-evacuation system. Microphone Echo Adjustment The front-panel MIC ECHO control allows adjustment of the microphone echo effect for suitable voice applications. For straightforward speech paging, use an appropriate setting that preserves announcement clarity. Individual Source Levels Separate microphone, auxiliary and media-player level controls allow compatible connected sources to be balanced before the final master volume is adjusted. Technical Specifications Brand TEXONIC Model / SKU PA260 Product Type 2-Zone Commercial Mixer Amplifier Rated Output Power 260W total Power Rating Condition 1kHz, THD+N = 1% Number of Zones 2 selectable zones Commercial Zone Outputs 100V Zone 1 / Zone 2 Additional Speaker Output Direct 100V Low-Impedance Output 4–16Ω Built-In Music Sources Bluetooth / FM / USB / SD Supported Audio Formats MP3 / WMA Microphone Channels 4 MIC1 / MIC2 Connections Front-panel ¼-inch (6.35mm) MIC3 / MIC4 Connections Rear-panel XLR / ¼-inch combo Phantom Power 48V switch for supported MIC inputs MIC1 Priority Selectable ON / OFF ducking AUX Inputs AUX1 / AUX2 Audio Outputs REC / LINE Additional Sound Functions Chime / Siren / Microphone Echo Tone Controls Bass / Treble Level Controls Microphone / AUX / Media / Master Output Monitoring Front-panel LED level meter Frequency Response 100Hz–15kHz (±3dB, 8Ω, 1W) THD+N ≤1% at 1kHz, half power Signal-to-Noise Ratio ≥50dB Line Input Sensitivity ≤350mV MIC Input Sensitivity ≤15mV Power Requirement AC 120V, 60Hz Dimensions (Inches) 16.93 × 3.46 × 12.99in Net Weight 10.5kg / 23.15lb Output Compatibility: Select a speaker output configuration that matches the connected speakers. Do not use the two-zone speaker configuration and low-impedance speaker configuration simultaneously. Understanding the Two Speaker Zones The PA260 provides separate front-panel switches for Zone 1 and Zone 2. Each zone represents a connected speaker circuit that can be enabled or disabled depending on the areas requiring music or announcements. Zone 1 — Main Area For example, the primary customer area, lobby, main workspace or larger common room. Zone 2 — Secondary Area For example, a staff room, reception, adjacent room or secondary commercial space. Available Zone Selection Zone 1 Only Send the amplifier's shared programme to Zone 1. Zone 2 Only Send the amplifier's shared programme to Zone 2. Both Zones Enable both areas to receive the same programme audio. Combined Amplifier Power Both zones share the amplifier's 260W rated capacity. Important: The PA260 does not provide separate music sources for each zone. It also does not have independent built-in volume controls for Zone 1 and Zone 2. Need Room-by-Room Volume Adjustment? Compatible 100V wall volume controls may be considered for suitable installations. Check the volume control power rating and the total speaker tap loading. Choosing Between Speaker Outputs Two 100V Zones Use for two selectable commercial speaker areas. Direct 100V Output Provides another documented 100V terminal option. Follow the manual's output wiring instructions. 4–16Ω Output For compatible low-impedance speaker arrangements. Correct Configuration Check amplifier terminals, speaker transformer settings and wiring before powering on. Speaker Connection Warning: Do not connect the two-zone speaker system and low-impedance speaker system at the same time. Turn off the amplifier before connecting or changing speaker wiring. 260W Speaker Loading & System Planning For 100V distributed audio, the speaker load is calculated by adding the selected transformer wattage taps of all connected speakers. The PA260 provides 260W of rated amplifier power shared across its speaker system. As a conservative system planning approach, allowing 20% amplifier headroom gives a suggested total connected 100V speaker tap load of approximately 208W. 260W Rated amplifier output 208W Conservative planning load 52W 20% planning headroom Planning Guideline: The 208W value is calculated using a conservative 20% power reserve. It is an installation design recommendation, not a separate manufacturer power rating. Example Two-Zone Speaker Installation Consider a business with two 100V speaker areas using commercial ceiling speakers set to 10W each. Area Speakers 100V Tap Zone Load Zone 1 — Main Area 10 10W 100W Zone 2 — Secondary Area 8 10W 80W Combined System 18 10W 180W This example produces a combined 180W speaker load, leaving 80W of unused rated amplifier capacity. Both zones can receive the same background music and paging programme when selected. More 100V Speaker Loading Examples Speakers Tap Each Total Load Capacity Remaining 6 6W 36W 224W 12 10W 120W 140W 16 10W 160W 100W 20 10W 200W 60W Speaker Selection: These examples apply only to compatible 100V speakers offering the stated transformer tap settings. Final speaker quantity and placement depend on coverage requirements, mounting height and background noise. Can I Connect Regular 8Ω Speakers? Yes. The PA260 provides a separate 4–16Ω low-impedance output for suitable speaker configurations. The total connected speaker impedance must remain within the amplifier's supported range. Do not use 100V transformer tap calculations for low-impedance speaker systems. Can I Connect Another Amplifier? Yes. The line output can feed compatible external audio equipment, including an additional commercial power amplifier or active subwoofer. The connected equipment must accept the appropriate line-level signal. Installation & Initial Setup Before operating the PA260, verify the speaker system, audio input connections and selected output mode. Before Turning On the Amplifier Disconnect AC power before working on speaker terminals. Confirm that 100V speakers are connected to the appropriate commercial speaker outputs. Check the transformer wattage tap settings of every connected speaker. Calculate the total speaker load across both zones. Check wiring polarity and inspect for short circuits. Verify the intended microphone and AUX connections. Enable phantom power only for suitable microphones. Start with microphone, media, AUX and master volumes at low levels. Keep the amplifier's ventilation areas clear. Testing the Two Zones Select a suitable audio source and activate Zone 1 only. Gradually increase the source and master volume to confirm normal sound. Repeat for Zone 2, then test both zones together at the intended operating level. Testing Microphone Priority Connect a compatible paging microphone to MIC1. Enable the rear MIC1 priority switch, play background music and make a test announcement. Confirm that the music level is reduced during the announcement. Installation Reminder: Never connect incompatible speaker output configurations at the same time. Incorrect wiring or speaker loading can damage audio equipment. Commercial Music Use: Businesses in Canada may need appropriate public-performance music licensing for background music or radio. Confirm the requirements applicable to the facility. What's Included 1 × TEXONIC PA260 260W 2-Zone Commercial Mixer Amplifier AC Power Cable User Manual Before Installation: Review the speaker output terminals, microphone input options, phantom power switch and MIC1 priority setting.

Variants (1)
  • Default Title — 511.00 USD — In stock

How AI sees this product

The more complete this product's details, the more confidently AI assistants can understand and recommend it.

81%