Enphase 3-Phase Q Cable Female Field Wireable Connector

Enphase 3-Phase Q Cable Female Field Wireable Connector

Brand: Enphase
SKU: Q-CONN-3P-10F
14.00 USD In stock Buy at Merchant

The Enphase IQ Field Wireable Three-Phase Female Connector (part number Q-CONN-3P-10F) is the female-gender field-wireable connector for three-phase Enphase Q Cable and IQ Cable installations. Part of the sixth-generation Enphase IQ System, it allows installers to terminate raw three-phase cable on-site at exactly the length required — eliminating pre-cut cable waste and enabling flexible AC wiring for arrays spread across multiple roof sections or buildings. Compatible with conductor sizes from 2.5mm² to 6mm² and cable outer diameters of 8–21mm, rated to 690V AC and 25A with an IP67 protection class. 690V AC Rated Voltage 25A Rated Current IP67 Protection Class -40 to +110°C Temperature Range ⚠ Never Connect or Disconnect Under Load: These connectors are not load-break rated. The Enphase system AC power must be fully disconnected before mating or separating connector pairs. Connecting or disconnecting under load risks arcing and damage to the connector contacts and to the microinverter AC circuitry. ⚠ Correct Phase Assignment Required: When assembling, match each conductor to the correct phase terminal (L1, L2, L3, Neutral) as labelled on the contact carrier. A phase mismatch will disrupt the phase balance of the three-phase microinverter circuit and can cause system errors or generation loss. ℹ Crimping Tool & Ferrules Required: Assembly requires a Multi-Contact PV-compatible crimping tool. For flexible conductors, Enphase recommends using ferrules to ensure a clean, reliable contact. Sold in packs of 10 — one connector per pack position. Female Socket — Q Cable Branch Connection The female Q-CONN-3P-10F connects to any open three-phase Q Cable connector port, allowing the installer to bring in a raw cable feed to that point in the branch. In combination with the male Q-CONN-3P-10M, it enables end-feed and center-feed configurations for three-phase microinverter branch circuits at any point along the array. Remote Array Section Connection Using mated pairs of male and female connectors, installers can bridge between separate sections of an array — for example, connecting a second roof slope or outbuilding array into the same three-phase Q Cable branch circuit. This eliminates the need for junction boxes and reduces overall system complexity. Wide Cable Compatibility Accepts cable outer diameters of 8–21mm and conductor cross-sections of 2.5mm² to 6mm². Works with Enphase three-phase raw Q Cable and compatible homerun cables. The three-phase Q Cable contains four flexible 2.5mm² conductors rated to 25A, with each connector supplying 230VAC L-N nominal per phase. Robust Weather & Temperature Rating Certified to IEC 61984 with IP67 protection and a temperature range of -40°C to +110°C (90°C wet/dry rating from Enphase EU documentation). This makes the Q-CONN-3P-10F fully suitable for exposed rooftop environments in all UK and European weather conditions. Technical Specifications — Q-CONN-3P-10F (Three-Phase Female Connector) Part Number Q-CONN-3P-10F Connector Gender Female (socket) Phase Configuration Three-phase (L1, L2, L3 + Neutral) Rated Voltage Up to 690V AC Rated Current 25A Protection Class IP67 (IEC 60529); also noted as IP66/IP68 in some regional documentation Temperature Range -40°C to +110°C; 90°C wet/dry rated (per Enphase EU store) Conductor Cross-Section 2.5mm² to 6mm² Cable Outer Diameter 8–21mm Certification IEC 61984 Assembly Tool Required Multi-Contact PV-compatible crimping tool Compatible Mating Connector Q-CONN-3P-10M (three-phase male) Disconnect Tool Q-DISC-3P-10 System Compatibility Enphase IQ System (6th-generation Q Cable / three-phase) What is the difference between Q-CONN-3P-10F and Q-CONN-10F? The Q-CONN-3P-10F is the three-phase female connector for three-phase Q Cable carrying L1, L2, L3, and Neutral. The Q-CONN-10F is the single-phase female connector for two-wire single-phase Q Cable. Always match the connector to your cable type. Do I need both male and female connectors for a field connection? Yes. For an end-feed or junction splice, you need one Q-CONN-3P-10M (male) and one Q-CONN-3P-10F (female). They mate together to form the complete electrical connection. Both parts are available separately from AIZO Quality Heating. What disconnect tool is needed for three-phase connectors? Use the Enphase Q-DISC-3P-10 three-phase disconnect tool. This is a different tool from the single-phase Q-DISC-10 and is specifically designed for the three-phase connector body. How many microinverters can a three-phase Q Cable branch support? A maximum 25A circuit breaker is required on each three-phase microinverter circuit. The maximum number of IQ Microinverters per circuit depends on the inverter model and output rating — refer to the Enphase Three-Phase Q Cable Design Technical Brief and use the Enphase Vrise Calculator to confirm your installation design.

Variants (1)
  • Default Title — 14.00 USD — In stock

AI Readiness

Good foundation, but some important product data is still missing.

83%