ABB AO815 3BSE052605R1 8 Channel Analog Output Module
ABB AO815 S800 I/O Analog Output Module The ABB AO815, also cataloged as the AO815 Analog Output Module (Article Number 3BSE052605R1), operates as a dedicated hardware component for converting digital control signals into unipolar 4-20 mA current outputs within ABB System 800xA and S800 I/O environments. Driving eight non-redundant unipolar channels, the module interfaces directly with field actuators, control valves, and positioners while providing point-to-point HART pass-through data transmission. Built-in cyclic self-diagnostics continuously monitor output circuitry, watchdog timers, checksum calculations, and internal power supply levels to maintain field signal execution. Hardware Specifications Parameter Specification Model AO815 Brand ABB Article Number 3BSE052605R1 Origin Sweden Weight 0.2 kg (0.44 lbs) Dimensions 45 mm x 119 mm x 102 mm (1.77 in x 4.68 in x 4.01 in) Operating Temp 0 deg C to +55 deg C (+32 deg F to +131 deg F) Power Consumption +5 V ModuleBus: Max 125 mA; +24 V external supply: Max 165 mA (Typ. 3.5 W) Output Channels 8 unipolar analog current outputs Output Signal Range 0-20 mA / 4-20 mA with point-to-point HART D/A Resolution 12-bit Maximum Load Impedance 750 Ohm Loop Accuracy Max error 0.1% Temperature Drift Max 50 ppm/deg C Signal Isolation Groupwise isolated from ground Update Cycle Time 10 ms Enclosure Rating IP20 (IEC 60529) Hazardous Location Class ATEX Zone 2, cULus Class 1 Div 2 / Zone 2 Deterministic ModuleBus Execution and Signal Integrity The AO815 routes digital control words across the internal rail using optimized backplane bus communication velocity, delivering reliable output updates every 10 ms across all eight channels. Onboard firmware flash compatibility permits live configuration updates and diagnostics processing without disrupting adjacent I/O modules on the same ModuleBus segment. Groupwise galvanic isolation protects internal logic circuits from field ground loops, preserving 12-bit resolution across long field runs up to 600 meters. Frequently Asked Questions Q: Does the AO815 module support redundant module pairing on S800 baseplates? A: No. The AO815 operates strictly in single (non-redundant) I/O configurations. Applications requiring dual-module redundancy must utilize the AO845 or AO845A module. Q: How does the AO815 handle point-to-point HART communications? A: The module passes digital HART FSK signals directly through the 4-20 mA loop wires, enabling connected field instruments to communicate diagnostics and configuration parameters directly to central software tools without external multiplexers. Q: What physical indications confirm an output circuit or watchdog fault on the module? A: The front panel includes dedicated LED indicators for Fault, Run, Warning, and Output Supervision, which immediately highlight internal transistor errors, short circuits, or watchdog execution trips. Field Installation Guidelines Mount the S800 terminal baseplate onto a standard 35 mm DIN rail, verifying that the mechanical earth grounding spring makes clean, paint-free contact with the metal rail surface. Align the rear connector pins of the AO815 module with the terminal block and press firmly until the locking clips click into place. Wire field actuator loops using twisted, shielded pair cabling. Connect all cable shields to the system ground bar using short, low-impedance grounding clamps. Ensure that the external +24 VDC process power supply delivers clean DC voltage capable of driving loop loads up to 750 Ohm. Provide a minimum vertical clearance of 50 mm above and below the module housing to enable passive thermal convection inside the enclosure.
Variants (1)
- Default Title — 188.00 USD — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.