500' 3/3C + 18/9C 8 AWG Ground Type TC/TC-ER-JP Generator Cable Grey 600V (100 amps, 17kW-24kW)

500' 3/3C + 18/9C 8 AWG Ground Type TC/TC-ER-JP Generator Cable Grey 600V (100 amps, 17kW-24kW)

Brand: Nassau National Cable
SKU: NNC20015X4500G
5100.00 USD In stock Buy at Merchant

[pdf] [/pdf] 3/3C + 18/9C 8 AWG Ground Type TC/TC-ER-JP Generator Cable Grey Applications: Multi-conductor all in one cable for connecting to a generator to a transfer switch. JP (Joist Pull) rated per NEC 336.10(9). UL listed as Type TC-ER-JP for applications not to exceed 600V. Also Known As: Generator Cable, Type TC/TC-ER-JP, Multi-Conductor Generator Cable, PVC Generator Cable, Type TC Cable, Type TC-ER Wire, Generator Wire, joist Pull Generator Cable, Copper Generator Cable, Generator Cable, W/G Generator Cable, 3/3C + 18/9C 8 W/G Cable, Grey Generator Cable. Construction: Conductors: • Element 1: Annealed bare copper Class C • Element 2: Annealed bare copper Class K • Element 3: Annealed bare copper Class C Insulation: • Element 1, 2 & 3: Polyvinylchloride (PVC) & Nylon Jacket: • Grey sunlight & flame resistant and direct burial approved PVC with ripcord rated 90°C wet or dry per UL 1277 Assembly: All 3 Elements or Conductors are cabled together with Non-Hygroscopic Polypropylene fillers as required for a circular cross-section with a clear mylar binder tape and jacketed Color Code: • Element 1: Black, Red, White • Element 2: Black, Red, Yellow, Yellow/Black, Blue, White, White/Blue, Purple, Purple/Black • Element 3: Green Ground Standards: • UL Listed as TC-ER-JP per UL Standard 1277 • Rated 90°C wet or dry to meet UL 83 for THHN/THWN • Meets cold bend test at -40°C • ICEA S-73-532. ICEA S-95-658, where applicable • Meets UL 1581 & 1202 (FT-4) 70,000 BTU/HR & ICEAT-29-520 210,000 BTU/HR requirements • REACH compliant per Regulation (EC) No 1907/2006 (235) Updated June 14, 2023 • Cable is suitable for use in Class I Division 2 hazardous locations • Element 1 & 2 conductors pass UL VW-1 flame test, rated THWN/VW-1 • ASTM B3, B8, B174, B787 • UL approved for Direct Burial & Sunlight Resistant Applications Specification: Size: 3 AWG (3 Conductors), 18 AWG (9 Conductors) Ground Wire Size: 8 AWG Jacket: Polyvinylchloride (PVC) & Nylon Jacket Thickness: 0.080 inches Jacket Color: Grey Outside Diameter: 0.983 inches Allowable Ampacity: 100 Amps Weight: 903/kft Rating: 17kW-24kW All values are nominal and subject to correction. *Ampacity according to NEC 310.15(B)(16) @30°C THWN 75°C insulated wires. **Installations shall follow NEC, applicable correcting factors shall be considered when conditions vary.

Variants (1)
  • Default Title — 5100.00 USD — In stock

How AI sees this product

The more complete this product's details, the more confidently AI assistants can understand and recommend it.

83%