AI880 3BSE028600R1 ABB High Integrity Analog Input Module
ABB AI880 High Integrity Analog Input Module Configured for high-integrity field signal acquisition in ABB System 800xA and S800 I/O platforms, the ABB AI880 (AI880 High Integrity Analog Input Module, Article Number 3BSE028600R1) provides direct physical/electrical execution across eight input channels. The unit converts analog sensor signals from 2-wire or 3-wire transmitters into digital values, distributing supervised, current-limited power directly to connected field devices. Compliant with NAMUR NE43 recommendations, the hardware executes configurable over-range and under-range monitoring while maintaining complete signal separation across the ModuleBus backplane. Hardware Specifications Parameter Specification Model AI880 Brand ABB Article Number 3BSE028600R1 Origin Sweden Weight 0.15 kg (0.33 lbs) Dimensions 45 mm x 119 mm x 102 mm (1.77 in x 4.68 in x 4.01 in) Operating Temp 0 deg C to +55 deg C (+32 deg F to +131 deg F) Power Consumption +5 V ModuleBus: Max 100 mA; +24 V external: Max 260 mA (Typ. 6 W) Number of Channels 8 analog input channels Signal Ranges -20 mA to +20 mA, 0-20 mA, 4-20 mA, -10 V to +10 V, 0-10 V, 2-10 V Input Resistance 250 Ohm (current mode), 200 kOhm (voltage mode) A/D Resolution 12-bit including sign Measurement Accuracy Max error 0.1% Temperature Drift Max 90 ppm/deg C Conversion Time Less than or equal to 1.5 ms Signal Isolation Channel-to-channel and channel-to-common galvanic isolation Enclosure Protection IP20 (IEC 60529) Hazardous Location Class ATEX Zone 2, cULus Class 1 Div 2 / Zone 2 Deterministic ModuleBus Execution and Transmitter Power Supervision The AI880 exchanges process image frames via deterministic backplane bus communication velocity, delivering digital signal conversions to the main processor within 1.5 ms. Onboard firmware flash compatibility enables live parameter updates and diagnostic processing for all eight channels. Internal power distribution supply loops feature active current limiting and continuous voltage supervision, protecting loop integrity against field-side short circuits while preventing ground loop propagation into backplane logic components. Frequently Asked Questions Q: How does the AI880 module handle signal out-of-range conditions per NAMUR NE43 standards? A: The AI880 detects extended current levels below 3.8 mA or above 20.5 mA, automatically flagging over-range, under-range, or open-circuit diagnostics over the ModuleBus without dropping channel execution. Q: Can the AI880 module supply power directly to 2-wire and 3-wire transmitters? A: Yes. The module features internal transmitter power distribution terminal rails that supply supervised, current-limited +24 VDC directly to field instruments without external distribution terminal blocks. Q: What redundancy options are available for the AI880 analog input module? A: The AI880 module supports both single (non-redundant) and dual-module redundant configurations on extended S800 baseplates for high-integrity process applications. Field Installation Guidelines Seat the S800 terminal baseplate onto a standard 35 mm DIN rail, verifying that the grounding contact spring establishes clean metal-to-metal bonding with the panel surface. Align the guide pins on the rear of the AI880 module with the baseplate socket, pressing firmly until the mechanical locking tabs snap into place. Route 4-20 mA or voltage signal cables in separate grounded raceways, keeping field lines away from high-voltage AC cables or variable-frequency drive outputs. Ground double-shielded twisted-pair cables at the system ground bar using low-impedance grounding clamps. Ensure that the internal transmitter power distribution load does not exceed power supply capacity. Maintain at least 50 mm of vertical ventilation space above and below the module for passive cooling up to +55 deg C.
Variants (1)
- Default Title — 188.00 USD — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.