Agilent 34907A Multifunction Module, DIO/Totalize/DAC for 34970A/34972A
Agilent 34907A Multifunction Module, DIO/Totalize/DAC for 34970A/34972A Product Overview Multifunction Module 16 bits of digital input and output 100 kHz totalizer input Two ±12V analog outputs The Agilent 34907A allows great flexibility for a variety of sense and control applications. The Agilent 34907A combines two 8-bit ports of digital input and output, a 100 kHz gated totalizer, and two ±12V analog outputs - all on a single earth-referenced module. The digital inputs and totalizer input may be included in a scan. Alarm limits for the digital and event counter inputs are evaluated continuously, capturing and logging alarm conditions even between scans. Digital Input/Ouput Use the digital outputs with an external power supply to control microwave switches and attenuators, solenoids, power relays, indicators, and more. Use-the digital inputs to sense limit switch and digital bus status. There are no complex handshake modes; reads and writes are initiated either from the front panel or the bus. Digital Input/Output Port 1, 2: 8 bit, input or output, nonisolated Vin(L): < 0.8V (TTL) Vin(H): > 2.0V (TTL) Vout(L): < 0.8V @ Iout = -400 mA Vout(H): > 2.4V @ Iout = 1 mA Vin(H) max: < 42V with external open drain pull-up Alarming: Maskable pattern match or state change Speed: 4 ms (max) alarm sampling Latency: 5 ms (typical) to 34970A alarm output Read/Write: Speed 95/s Totalize Input Count-events from devices like photo interrupters, limit-switches, and Hall-effect sensors. It-keeps an updated total which can be read via the front panel or programmatically at any time. With 26 bits of resolution, it can count events at full speed for nearly 11 minutes without an overflow. Totalize Input Max Count: 226 - 1 Totalize Input: 100 kHz (max) Rising or falling edge, programmable Signal level: 1 Vp-p (min) 42 Vpk (max) Threshold: 0V or TTL, jumper selectable Gate Input: TTL-Hi, TTL-Lo, or none Count Reset: Manual or Read + Reset Read Speed: 85/s Analog Output Use the two electronically calibrated analog outputs to source bias voltages to your device under test, to control your analog programmable power supplies, or use the outputs as setpoints for your control systems. The outputs are programmed directly in volts, either from the front panel or from the bus. Analog Output DAC 1, 2: ± 12V, nonisolated Resolution: 1 mV IOUT: 10 mA max Settling time: 1 ms to 0.01% of output Accuracy: ±(% of output + mV) 1 year ±5°C: 0.25% + 20 mV Temp. Coefficient: ± ( 0.015% + 1 mV)/°C
Variants (1)
- Default Title — 75.00 USD — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.