Leak KNX 2.0

Leak KNX 2.0

Brand: Elsner
SKU: EL-70316
272.00 GBP In stock Buy at Merchant

The Leakage sensor Leak KNX 2.0 includes an evaluation unit and a probe. If there is water between the electrodes of the probe, the evaluation unit produces an acoustic alarm. Additionally, the alarm signal is sent to the KNX bus. Even if no probe is connected or the cable is defective, the alarm can be sounded and signalled on the bus. Functions Detection of water on the probe Acoustic alarm signal by the evaluation unit during a water alarm (sustained beeping tone). Short beeping during the follow-up time (1 minute after the end of the alarm). Alarm signal sent to the KNX bus with a text message Detection whether probe is connected and the probe cable is functional Acoustic alarm signal on the evaluation unit when the probe is not connected or when the probe cable is broken (long beeps) 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 16 logic inputs in the form of communication objects, may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits Configuration is made using the KNX software ETS 5. Evaluation Unit: General: Housing plastic Colour grey Degree of protection IP20 Dimensions (W x H x D) 105 mm × 105 mm × 65 mm Total weight ≈ 180 g Ambient temperature -5…+45°C Ambient humidity (RH) (non-condensing) 0...95 % Storage temperature -25...+70°C Protective class II Overvoltage category III Pollution degree 2 KNX bus: Medium TP1-256 Configuration mode S-Mode Group addresses max. 252 Assignments max. 252 Communication objects 55 Nominal voltage 30V DC SELV Power consumption ≤ 10 mA Connection KNX plug-in terminal Conductor diameter Stripping length 0.6…0.8 mm s 5 mm Duration after bus voltage restoration until data is received ≈ 4 s Supply: Voltage 20...32V DC SELV Current [at] no alarm alarm [24 V DC ±10%] ≤ 15mA ≤ 30mA Probe input: Electrode probe, with BNC terminal 1 × Probe: General: Casing / electrodes: stainless steel A2 Degree of protection IP68 Electrode chemical resistance Water Dimensions Diameter Height 77 mm 33 mm Cable length (plus cable grip and plugs) Extendable to ≈ 140cm 10m Total weight ≈ 200 g Ambient temperature -25…+50°C Storage temperature -30...+70°C Scope Of Supply Evaluation unit Probe with BNC cable Stainless steel A2 plumbing screw 4.5 x 70 (DIN 7995), matching dowel SX6 x 30 Data sheet with installation instruction (German, English, French, Italian, Spanish) Manual (German, English) as download Product file for ETS 5 (German) as download

Variants (1)
  • Default Title — 272.00 GBP — In stock

AI Readiness

Good foundation, but some important product data is still missing.

83%