Easesyn ES50A-VET Handheld Patient Monitor ICU Vital Signs Veterinary animals Monitor 6 Parameters 5''

Easesyn ES50A-VET Handheld Patient Monitor ICU Vital Signs Veterinary animals Monitor 6 Parameters 5''

Brand: CONTEC
SKU: 3.05.071.05.004
559.00 USD In stock Buy at Merchant

Function Parameters: ECG, RESP, SpO2, PR, NIBP, TEMP, CO2 (optional) 1)ECG Heart rate (HR) ECG waveform 2)RESP Respiration rate (RR) Respiration waveform 3)SpO2 Oxygen saturation (SpO2) Plethysmogram (PLETH) waveform Pulse rate (PR) Bar graph 4)NIBP Systolic pressure (SYS), Diastolic pressure (DIA), Mean pressure (MEAN) 5)TEMP 6)CO2 (optional) EtCO2, INSCO2, AWRR It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation. Performance ▲ECG Lead mode: 3-lead: I, II, III 5-lead: I, II, III, aVR, aVL, aVF, V Waveform: 3-lead, 1 channel 5-lead, 2-channel Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV Scan speed: 12.5 mm/s, 25 mm/s, 50 mm/s HR Measurement and alarm range: Adult: 15 ~ 300 bpm Pediatric/neonate: 15 ~ 350 bpm Accuracy: ± 1 % or ± 1 bpm, whichever is greater Resolution: 1 bpm ▲RESP Method: R-F (RA-LL) impedance Respiration rate: Measurement and alarm range: 0 ~ 150 rpm Resolution: 1 rpm Accuracy: 7 rpm ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater; 0 rpm ~ 6 rpm, unspecified Apnea alarm: 10 ~ 40 s Scan speed: 12.5 mm/s, 25 mm/s ▲NIBP Measurement mode: Oscillometry Working mode: Manual / AUTO / STAT Measurement interval in AUTO mode: 1 / 2 /3 / 4 / 5/ 10 / 15 / 30 / 60 / 90 / 120 / 180 / 240 / 480 minutes Measurement period in STAT mode: 5 minutes Measurement and alarm range: 0 ~ 300 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ± 3 mmHg Measurement accuracy: Maximal mean deviation: ± 5 mmHg Maximal standard deviation: 8 mmHg Over-pressure protection: Adult: 297±3 mmHg Pediatric: 260±3 mmHg Neonate: 147±3 mmHg ▲SpO2 Measurement and alarm range: 0 ~ 100% Resolution: 1 % Accuracy: 70 % ~ 100 %: ± 2 %; 0 % ~ 69 %: unspecified ▲PR Measurement and alarm range: 25 ~ 250 bpm Accuracy: ± 2 bpm or ± 2 %, whichever is greater ▲TEMP Measurement and alarm range: 0 ~ 50 ℃ Resolution: 0.1 ℃ Accuracy: ± 0.1 ℃ ▲CO2(optional) Measurement mode: mainstream or sidestream Measurement range: 0 ~ 150 mmHg Resolution: 0.1 mmHg: 0 ~ 69 mmHg 0.25 mmHg: 70 ~ 150 mmHg Accuracy: 0 ~ 40 mmHg: ±2 mmHg 41 ~ 70 mmHg: ±5 % 71 ~ 100 mmHg: ±8 % 101 ~ 150 mmHg: ±10 % AwRR measurement range: Sidestream: 2 ~ 120 rpm Mainstream: 2 ~ 150 rpm Accuracy: ±1 rpm Apnea alarm: yes ▲Power supply: 100 V-240 V ~ 50 Hz/60 Hz ▲Safety class: Class II Accessories 1)VET SpO2 probe 1)VET NIBP cuff 2)NIBP extension tube 2)ECG lead cable 3)ECG electrode clips 4)TEMP probe 3)Power cord 4)User Manual Physical characteristic Dimension: 168 mm (L) × 56 mm (W) × 98 mm (H) Weight: <1.0 Kg (excluding accessories)

Variants (1)
  • Default Title — 559.00 USD — In stock

How AI sees this product

The more complete this product's details, the more confidently AI assistants can understand and recommend it.

84%