Repeater Pipette (Stepper Pipette) for Repetitive Dispensing

Repeater Pipette (Stepper Pipette) for Repetitive Dispensing

0.00 GBP In stock Buy at Merchant

Repeater Pipette (Stepper Pipette) for Repetitive Dispensing 10μL – 5mL dispensing range Up to 48 consecutive steps Compatible with 0.5mL – 50mL tips Lightweight & robust design Secure tip stop lever Product Overview The Hawach Repeater Pipette is a manual positive displacement pipette designed for repetitive dispensing of liquids from 10 μL to 5 mL. By aspirating liquid once and dispensing multiple equal aliquots without refilling, it significantly improves workflow efficiency and reduces operator fatigue during repetitive laboratory procedures. Compatible with disposable dispenser tips ranging from 0.5 mL to 50 mL, the pipette supports up to 48 dispensing cycles from a single aspiration. It is suitable for aqueous, viscous, volatile, and foaming liquids, making it ideal for clinical diagnostics, molecular biology, pharmaceutical research, chemical analysis, food testing, and industrial quality control laboratories. Its lightweight ergonomic design, secure tip locking mechanism, and reliable positive displacement principle ensure accurate and reproducible dispensing performance even when handling challenging liquid types. Key Features Slim, Light & Robust Designed for comfortable, fatigue-free operation during extended repetitive dispensing sessions. The lightweight body reduces hand strain while maintaining durability for daily laboratory use. Wide Dispensing Volume Covers a broad volume range from 10μL to 5mL, accommodating diverse experimental needs from micro-volume assays to larger reagent transfers. Up to 48 Dispensing Steps Single aspiration enables up to 48 consecutive dispensing steps without refilling, streamlining lengthy workflows and improving efficiency. Secure Tip Stop Lever Equipped with a durable dispenser tip stop lever that securely locks disposable polypropylene dispenser tips in place, preventing accidental detachment during use. Versatile Tip Compatibility Compatible with a variety of disposable polypropylene dispenser tips ranging from 0.5mL to 50mL, providing flexibility across different volume requirements. Positive Displacement Principle Based on the positive displacement principle, this repeater pipette ensures accurate dispensing regardless of liquid density, viscosity, or volatility – ideal for challenging liquids. Applications Clinical & Hospital Labs Serial dispensing of diagnostic reagents, sample aliquoting, and high-throughput testing. Biological Research Filling microplates, nucleic acid purification kits, and cell culture media preparation. Chemical Analysis Reagent dispensing for analytical chemistry, quality control, and formulation development. Food & Beverage QC Repetitive addition of standards, buffers, and additives in quality testing workflows. Pharmaceutical Industry Serial dispensing for drug formulation, dissolution testing, and stability studies. Repeater Pipette vs Standard Pipette Feature Repeater Pipette Standard Micropipette Repeated Dispensing Excellent Limited High-Throughput Workflows Excellent Moderate Operator Fatigue Low Higher Viscous Liquids Excellent Limited Volatile Liquids Excellent Limited Reagent Aliquoting Ideal Acceptable For laboratories performing repetitive liquid dispensing, a repeater pipette offers higher efficiency, improved consistency, and reduced hand strain compared with conventional air displacement micropipettes. How to Select the Dispensing Volume Find the required dispensing volume in the table below. Use the volume selection dial to set the corresponding volume setting (1-5). Select and insert a suitable dispenser tip (0.5mL to 50mL). Follow the maximum dispensing steps as stated in the table for the chosen setting. Tip Volume Setting 1 Setting 2 Setting 3 Setting 4 Setting 5 0.5 mL 10 μL 20 μL 30 μL 40 μL 50 μL 1.25 mL 25 μL 50 μL 75 μL 100 μL 125 μL 2.50 mL 50 μL 100 μL 150 μL 200 μL 250 μL 5.00 mL 100 μL 200 μL 300 μL 400 μL 500 μL 12.50 mL 250 μL 500 μL 750 μL 1000 μL 1250 μL 25.00 mL 500 μL 1000 μL 1500 μL 2000 μL 2500 μL 50.00 mL 1000 μL 2000 μL 3000 μL 4000 μL 5000 μL Steps 48 23 15 11 8 Note: The number of dispensing steps indicates how many aliquots can be dispensed from a single tip fill at the corresponding setting. Tip Compatibility The Hawach Repeater Pipette is designed for use with disposable positive displacement dispenser tips. Multiple tip capacities are available to cover a wide range of repetitive dispensing applications. Dispenser Tip Capacity Typical Dispensing Range 0.5 mL 10-50 μL 1.25 mL 25-125 μL 2.5 mL 50-250 μL 5 mL 100-500 μL 12.5 mL 250-1250 μL 25 mL 500-2500 μL 50 mL 1000-5000 μL Accuracy & Precision The Hawach Repeater Pipette is factory calibrated to provide reliable dispensing accuracy and reproducibility across the entire operating range. Performance Parameter Specification Accuracy (A%) ±0.8% Precision (CV%) ≤0.7% Calibration Factory calibrated before shipment Operating Principle Positive displacement dispensing Technical Specifications Dispensing Volume Range 10 μL – 5 mL (depending on tip and dial setting) Maximum Dispensing Steps Up to 48 steps per single aspiration Compatible Tips Disposable polypropylene dispenser tips: 0.5 mL, 1.25 mL, 2.5 mL, 5 mL, 12.5 mL, 25 mL, 50 mL Tip Stop Mechanism Durable dispenser tip stop lever for secure locking Operating Principle Positive displacement / forward pipetting principle Design Slim, lightweight, robust Applications Clinical, biological, chemical, food & beverage, pharmaceutical laboratories Why Choose the Hawach Repeater Pipette Eliminates Refilling Between Steps Aspirate once and dispense up to 48 times – significantly reducing handling time and improving workflow efficiency. Reduces Repetitive Strain Lightweight design and smooth operation minimize hand fatigue during long dispensing series, protecting operator health. Minimizes Errors By reducing the number of fill/dispense sequences, the repeater pipette lowers the risk of volume errors and improves consistency across samples. Cost-Effective Alternative When multichannel pipettes are outside of budget, repeater pipettes offer a cost-effective method to increase repetitive dispensing efficiency. Versatile Liquid Handling Suitable for a wide range of liquids – including viscous, volatile, and foaming samples – when used with appropriate dispenser tips. Reduced Consumable Waste One disposable tip can be used for many dispensing steps, reducing plastic waste compared to changing tips for each individual transfer. ISO 9001 Factory Factory Calibrated CE Compliant OEM Available Frequently Asked Questions What is a repeater pipette used for? A repeater pipette is used to dispense the same liquid volume multiple times from a single aspiration. It is commonly used for microplate filling, reagent aliquoting, serial dispensing, and high-throughput laboratory workflows. What is the difference between a repeater pipette and a standard micropipette? A standard micropipette requires a new aspiration before every dispense. A repeater pipette allows multiple dispensing cycles after one aspiration, significantly increasing efficiency for repetitive liquid handling tasks. Can this repeater pipette handle viscous or volatile liquids? Yes. The positive displacement operating principle enables accurate dispensing of viscous, volatile, foaming, and high-density liquids when used with compatible dispenser tips. How many dispensing cycles can be performed from one aspiration? Depending on the selected dial setting and dispenser tip size, up to 48 dispensing cycles can be performed from a single aspiration. What dispenser tip sizes are available? Compatible dispenser tips are available in capacities of 0.5 mL, 1.25 mL, 2.5 mL, 5 mL, 12.5 mL, 25 mL, and 50 mL. Ordering Information Model Description 21041001 Repeater Pipette, 10 μL-5 mL, Manual Positive Displacement Type OEM & Private Label Available Custom branding and packaging Bulk quantity discounts Distributor support available Factory-direct supply Contact Hawach for a Quotation Enter your email address and our sales staff will contact you as soon as possible. Your Email (required) Your Message (required) Δ document.getElementById( "ak_js_5" ).setAttribute( "value", ( new Date() ).getTime() ); ×

AI Readiness

Good foundation, but some important product data is still missing.

66%