VentPlus CO2 Monitor and Controller for Healthy Indoor Air, Mushroom Farms & Greenhouses

VentPlus CO2 Monitor and Controller for Healthy Indoor Air, Mushroom Farms & Greenhouses

0.00 INR In stock Buy at Merchant

:root { –brand-blue: #1e73be; –brand-blue-dark: #0d4b8a; –brand-orange: #e85d04; –text-dark: #333333; –text-muted: #666666; –bg-light: #f7f9fc; –border: #e0e6ed; –green: #2e8b57; –red: #d9534f; } * { box-sizing: border-box; } body { font-family: ‘Roboto’, ‘Open Sans’, -apple-system, BlinkMacSystemFont, ‘Segoe UI’, sans-serif; color: var(–text-dark); line-height: 1.7; margin: 0; background: #fff; font-size: 16px; } .product-page { max-width: 1140px; margin: 0 auto; padding: 24px 20px 60px; } /* Breadcrumb */ .breadcrumb { font-size: 14px; color: var(–text-muted); margin-bottom: 16px; } .breadcrumb a { color: var(–brand-blue); text-decoration: none; } /* H1 */ h1 { font-size: 32px; font-weight: 700; color: var(–brand-blue-dark); line-height: 1.25; margin: 0 0 14px; } /* Tag list (matches your existing style) */ .tags { font-size: 13px; margin-bottom: 22px; color: var(–text-muted); } .tags strong { color: var(–text-dark); } .tags a { color: var(–brand-blue); text-decoration: none; padding: 1px 2px; } .tags a:hover { text-decoration: underline; } /* Product image gallery */ .gallery { display: grid; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)); gap: 12px; margin-bottom: 32px; } .gallery img { width: 100%; height: auto; border-radius: 6px; border: 1px solid var(–border); } /* Tabs (matches WooCommerce-style) */ .tabs { border-bottom: 2px solid var(–border); margin: 32px 0 24px; display: flex; gap: 4px; } .tab { padding: 10px 20px; background: var(–bg-light); border: 1px solid var(–border); border-bottom: none; border-radius: 4px 4px 0 0; cursor: pointer; font-weight: 500; color: var(–text-muted); } .tab.active { background: #fff; color: var(–brand-blue-dark); border-bottom: 2px solid #fff; margin-bottom: -2px; font-weight: 600; } /* Section headings */ h2 { color: var(–brand-blue-dark); font-size: 26px; font-weight: 700; margin: 36px 0 12px; padding-bottom: 8px; border-bottom: 2px solid var(–brand-orange); display: inline-block; } h3 { color: var(–brand-blue); font-size: 20px; font-weight: 600; margin: 24px 0 8px; } h4 { color: var(–brand-blue-dark); font-size: 17px; font-weight: 600; margin: 18px 0 6px; } p { margin: 0 0 14px; } ul, ol { margin: 0 0 16px; padding-left: 22px; } ul li, ol li { margin-bottom: 6px; } strong { color: var(–brand-blue-dark); } em { color: var(–text-dark); } /* Pro Tip / Callout boxes */ .pro-tip { background: #fff8f0; border-left: 4px solid var(–brand-orange); padding: 14px 18px; margin: 18px 0; border-radius: 0 4px 4px 0; } .pro-tip strong { color: var(–brand-orange); } .case-study { background: var(–bg-light); border-left: 4px solid var(–brand-blue); padding: 18px 22px; margin: 20px 0; border-radius: 0 6px 6px 0; } .alert-warning { background: #fff4e6; border: 1px solid #ffd9a8; padding: 12px 16px; border-radius: 4px; margin: 16px 0; } /* Tables (matches your existing style) */ table { width: 100%; border-collapse: collapse; margin: 16px 0 24px; font-size: 15px; } table th { background: var(–brand-blue-dark); color: #787878; text-align: left; padding: 10px 14px; font-weight: 600; } table td { padding: 10px 14px; border-bottom: 1px solid var(–border); vertical-align: top; } table tr:nth-child(even) td { background: var(–bg-light); } /* Comparison table check/cross */ .check { color: var(–green); font-weight: 700; } .cross { color: var(–red); font-weight: 700; } /* Application cards grid */ .app-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(260px, 1fr)); gap: 18px; margin: 20px 0 28px; } .app-card { background: #fff; border: 1px solid var(–border); border-top: 4px solid var(–brand-blue); padding: 18px 20px; border-radius: 6px; transition: box-shadow 0.2s, transform 0.2s; } .app-card:hover { box-shadow: 0 4px 16px rgba(30, 115, 190, 0.12); transform: translateY(-2px); } .app-card h4 { margin-top: 0; color: var(–brand-blue-dark); font-size: 17px; } .app-card p { font-size: 14px; color: var(–text-muted); margin-bottom: 0; } /* CO2 level reference table */ .ppm-table tr.safe td:first-child { border-left: 4px solid var(–green); } .ppm-table tr.warn td:first-child { border-left: 4px solid #f5a623; } .ppm-table tr.danger td:first-child { border-left: 4px solid var(–red); } /* CTA box */ .cta-box { background: linear-gradient(135deg, var(–brand-blue-dark), var(–brand-blue)); color: #fff; padding: 28px 30px; border-radius: 8px; margin: 32px 0; text-align: center; } .cta-box h3 { color: #172e45; margin-top: 0; } .cta-box p { color: #4d7ba8; } .cta-box a.btn { display: inline-block; background: var(–brand-orange); color: #fff; padding: 12px 28px; border-radius: 4px; text-decoration: none; font-weight: 600; margin-top: 10px; transition: background 0.2s; } .cta-box a.btn:hover { background: #b84a03; } /* FAQ accordion */ .faq-item { border: 1px solid var(–border); border-radius: 4px; margin-bottom: 10px; overflow: hidden; } .faq-item summary { padding: 12px 18px; background: var(–bg-light); cursor: pointer; font-weight: 600; color: var(–brand-blue-dark); list-style: none; position: relative; } .faq-item summary::-webkit-details-marker { display: none; } .faq-item summary::after { content: ‘+’; position: absolute; right: 18px; color: var(–brand-orange); font-size: 20px; font-weight: 700; } .faq-item[open] summary::after { content: ‘−’; } .faq-item .faq-body { padding: 14px 18px; } /* Download link */ .download-link { display: inline-block; background: var(–brand-blue-dark); color: #fff !important; padding: 10px 22px; border-radius: 4px; text-decoration: none; font-weight: 600; margin: 14px 0; } .download-link:hover { background: var(–brand-blue); } hr.divider { border: none; border-top: 1px solid var(–border); margin: 32px 0; } @media (max-width: 768px) { h1 { font-size: 26px; } h2 { font-size: 22px; } .product-page { padding: 16px 14px 40px; } } VentPlus Smart CO2 Monitor & Controller: Automated Ventilation for Healthy Indoor Air High carbon dioxide (CO2) levels in offices, homes, schools and farms lead to fatigue, headaches, poor concentration, and crop losses. The VentPlus CO2 monitor and controller is a professional-grade carbon dioxide meter that automatically manages your indoor air quality (IAQ) by triggering ventilation exactly when needed — whether you need to lower CO2 in a meeting room or maintain CO2 in a mushroom farm or greenhouse. Modern office spaces and homes in India are increasingly designed with sealed façades and energy-efficient modular windows to maximize thermal efficiency and noise insulation. However, this architectural trend significantly restricts natural air exchange. As a result, carbon dioxide (CO₂) — a colorless and odorless gas — becomes a silent threat, accumulating rapidly within the indoor environment. In high-occupancy areas such as meeting rooms, conference halls, restaurants, bars, gyms, and banquet halls, as well as bedrooms where the door remains closed for nearly 8 hours at night, CO₂ levels surge due to human respiration. In a typical meeting room with 8–12 occupants, levels starting at 600–800 ppm can skyrocket to 2,500 ppm within just 60–90 minutes. During peak hours, restaurants and bars frequently exceed 2,000 ppm, while large gatherings in banquet halls can cross 3,000 ppm. Without an active CO2 ppm meter and automatic ventilation controller, these dangerous concentrations remain completely undetected. Why Indoor Air Quality (IAQ) Matters In modern, airtight buildings, indoor carbon dioxide levels can quickly exceed 1,500 ppm, leading to “Sick Building Syndrome” — characterized by headaches, eye irritation, dizziness, nausea, and fatigue. By maintaining CO2 levels below 1,000 ppm with a reliable CO2 monitor and automatic ventilation controller, you ensure a safer, more productive environment for everyone. CO₂ is the primary indicator of ventilation adequacy. When levels rise, cognitive functions suffer. Research from the Harvard COGfx Study and ASHRAE proves that cognitive performance can decline by 15% to 50% at elevated CO2 levels, directly impacting meeting efficiency, decision-making, and employee output. CO2 ppm Reference Chart for Indoor Spaces CO2 Level (ppm) Status Effect on Human Health & Cognition 400 – 600 ppm Excellent Outdoor / well-ventilated air. Optimal for productivity and sleep. 600 – 1,000 ppm Acceptable ASHRAE & WHO recommended range for indoor air quality. 1,000 – 1,500 ppm Marginal Drowsiness, mild fatigue, reduced concentration begin to appear. 1,500 – 2,500 ppm Poor Headaches, sleepiness, stagnant air, decision-making impaired. 2,500 – 5,000 ppm Very Poor Strong cognitive impairment, prolonged exposure causes health symptoms. > 5,000 ppm Hazardous Workplace exposure limit (OSHA). Avoid for safety. Pro Tip: Most international standards (ASHRAE Standard 62.1 and WHO Air Quality Guidelines) recommend keeping indoor CO2 between 600 and 1,000 ppm for optimal human health, productivity, and cognitive performance. Case Study: Boosting Office Productivity with VentPlus The Challenge: A mid-sized software firm in Bangalore noticed a significant “afternoon slump” where employees reported headaches and drowsiness after 2:00 PM. The Solution: They installed the VentPlus CO2 Monitor and Controller connected to two wall-mounted exhaust fans. The “On” trigger was set to 1,000 ppm and the “Off” trigger to 700 ppm. The Result: Energy Savings: Fans only ran for 15 minutes every hour instead of 24/7. Employee Wellness: Reported afternoon headaches dropped by over 60%. Automation: The facility manager no longer had to manually check ventilation. How the VentPlus CO2 Monitor & Controller Works It’s a simple 3-step process to automate your air quality with this carbon dioxide meter: Monitor: High-accuracy NDIR (Non-Dispersive Infrared) CO2 sensor tracks carbon dioxide concentration in real-time, along with temperature and humidity. Trigger: Plug your exhaust fan, fresh-air fan, or CO2 generator into the built-in AC socket. Configure your custom ON and OFF ppm thresholds. Ventilate: The system turns the fan ON when CO2 exceeds the upper limit and OFF once levels return to the safe range — fully automatic, 24×7. VentPlus CO2 monitor and controller for healthy indoor air enables better air, better health, better decisions, and better business. Applications of the VentPlus CO2 Controller VentPlus is a versatile carbon dioxide monitor and ventilation controller built for the wide range of Indian environments — from urban offices to agricultural farms to defense installations. 1. Offices, IT Parks & Co-working Spaces Modern Indian offices, IT parks, BPOs and co-working spaces (such as those operated by WeWork, Awfis, IndiQube and 91springboard) use sealed HVAC systems where carbon dioxide accumulates rapidly during meetings. VentPlus continuously monitors CO2 ppm levels and triggers exhaust fans to maintain ASHRAE-recommended air quality — reducing the post-lunch “2 PM slump”, headaches, and absenteeism while improving employee productivity by up to 50% according to Harvard COGfx research. 2. Homes, Apartments & Bedrooms In urban Indian apartments with closed bedrooms and centralized AC, CO2 levels can cross 1,500–2,000 ppm during 8 hours of sleep — directly affecting sleep quality and morning freshness. The VentPlus CO2 monitor for bedrooms automatically activates a fresh air fan or exhaust to maintain healthy carbon dioxide levels, ideal for premium homes, smart homes, and elderly care setups. 3. Schools & Classrooms Classrooms with 30+ students often exceed 2,500 ppm CO2 within an hour, directly affecting students’ attention, learning ability, and exam performance. VentPlus is an ideal classroom CO2 monitor for CBSE, ICSE and international schools, daycares, and coaching institutes — a simple installation provides parents and trustees a visible, measurable commitment to children’s health. 4. Mushroom Farm CO2 Controller (Oyster, Button, Shiitake, Milky) Mushroom cultivation is one of the fastest-growing agriculture sectors in India — the market is currently valued at ₹1,200 crore and growing at 15% annually, driven by oyster mushrooms in North India, button mushrooms in Himachal Pradesh, milky mushrooms in South India, and shiitake exports from Uttarakhand. Carbon dioxide (CO2) is the single most important environmental parameter during the fruiting stage of any commercial mushroom farm. Why mushroom farms need a CO2 controller: Spawn run / colonization stage: CO2 above 5,000 ppm is fine and even beneficial. Pinning stage: CO2 must drop below 1,500 ppm or pinheads will abort. Fruiting / maturation stage: CO2 must stay below 1,000 ppm to prevent elongated, trumpet-shaped mushrooms with small caps — a defect that drastically reduces market value. The VentPlus mushroom farm CO2 controller automatically operates the exhaust fan whenever CO2 crosses your stage-specific threshold and shuts it off when the level falls — ensuring proper pinhead formation, uniform cap size, and premium quality yield for oyster, button, milky and shiitake mushrooms. Suitable for grow rooms, fruiting chambers, Phase II tunnels, and small-batch home cultivation in Bangalore, Mumbai, Delhi NCR, Pune, Hyderabad and other urban centers. Bonus: VentPlus also displays temperature and humidity — three of the four critical parameters for mushroom growing — on the same LCD screen, eliminating the need for separate instruments. 5. Greenhouse & Polyhouse CO2 Controller In commercial greenhouses, polyhouses and naturally ventilated farms across India — from Maharashtra’s flower-growing belts to Karnataka’s vegetable polyhouses to Punjab’s hydroponic operations — CO2 enrichment is the most cost-effective way to increase crop yield by 20–40%. Plants in a closed greenhouse can deplete CO2 below 200 ppm within 1–2 hours of sunlight, starving photosynthesis and stunting growth. The VentPlus greenhouse CO2 controller is designed to maintain CO2 above a target level rather than below — ideal for: Hi-tech polyhouses growing tomatoes, capsicum, cucumber, lettuce, and exotic vegetables Flower greenhouses (rose, gerbera, carnation, chrysanthemum) Vertical farms and urban indoor agriculture Tissue culture rooms and propagation chambers Typical CO2 enrichment range is 800–1,500 ppm during daylight hours. VentPlus continuously monitors carbon dioxide and triggers your CO2 generator, propane burner, or compressed CO2 cylinder solenoid to maintain optimal photosynthesis. 6. Hydroponic Grow Room & Grow Tent CO2 Controller Hydroponic and indoor cultivation in India is booming — from leafy green farms in Mumbai and Delhi NCR to research and propagation grow rooms in Bengaluru and Hyderabad. In a sealed grow room or grow tent, CO2 enrichment between 1,000 and 1,500 ppm can boost yield by 30% or more compared to ambient (~420 ppm) conditions. The VentPlus hydroponic CO2 controller is plug-and-play, requires no PLC or HVAC controller, and works with: Indoor leafy greens and herbs (lettuce, basil, kale, mint) Vertical farming racks and grow tents Tissue culture and plant propagation rooms Indoor floriculture and horticulture R&D setups 7. Hospitals, Clinics & Waiting Rooms Post-COVID, indoor air quality in healthcare facilities has become a top priority. CO2 levels in crowded OPD waiting rooms, dental clinics, day-care wards, and physiotherapy centers regularly exceed 2,000 ppm, increasing infection risk and patient discomfort. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) explicitly recommends CO2-based demand-controlled ventilation in healthcare environments. VentPlus serves as a reliable hospital CO2 monitor for: OPD waiting rooms and reception areas Dental and physiotherapy clinics IVF and fertility clinics (where CO2 control is mission-critical) Diagnostic centers, pathology labs, and dialysis units Old-age homes, palliative care and rehabilitation centers 8. Banquet Halls, Restaurants, Bars & Auditoriums Banquet halls, wedding venues, restaurants, bars, lounges, cinemas, and conference auditoriums host high-density occupancy where CO2 levels can shoot from 600 to over 3,000 ppm within an hour. Guests notice the stuffy, stale feeling but rarely know the cause. VentPlus discreetly monitors carbon dioxide and triggers fresh-air supply or exhaust fans automatically, ensuring a comfortable atmosphere for guests — and protecting your venue’s reputation. Ideal for: Banquet halls and wedding venues Fine-dining restaurants, cafés and lounges Pubs, bars and nightclubs Cinema halls and multiplexes Auditoriums, seminar halls and conference centers 9. Gyms, Yoga Studios & Fitness Centers During an intense workout, a single person can exhale 10× more CO2 than at rest. In a typical group fitness class, Zumba session, hot yoga room, or CrossFit studio, CO2 can cross 3,000 ppm within 30 minutes — directly reducing oxygen availability, increasing perceived exertion, and limiting workout performance. The VentPlus gym CO2 monitor automatically activates exhaust fans during peak class hours and switches them off when the room is empty, also saving energy. Ideal for: Gyms, CrossFit boxes and HIIT studios Yoga and pilates studios (including hot yoga rooms) Dance studios and Zumba centers Spinning classes and indoor cycling studios Sports clubs and indoor training facilities 10. Army Bunkers, Barracks & Defense Installations Army bunkers, underground command posts, military barracks, and defense control rooms are often sealed environments with limited ventilation — making them especially prone to dangerous CO2 buildup. The VentPlus CO2 controller is ruggedly built for 24×7 operation and is currently used in army bunkers and barracks to automatically activate exhaust ventilation whenever CO2 exceeds safe thresholds, protecting soldier alertness, cognitive performance, and decision-making in critical operations. Applications include: Forward bunkers and underground shelters Defense barracks and dormitories Naval submarines and confined-space installations Military command and control rooms Paramilitary and police accommodations 11. Cold Storage, Food Warehouses & Confined Spaces Cold storage facilities, food warehouses, fruit ripening chambers, and refrigerated processing rooms — common across India’s growing cold-chain logistics sector — face two CO2-related risks: (1) worker safety, since CO2 from respiration and dry ice can accumulate to dangerous levels in confined spaces, and (2) controlled atmosphere storage, where CO2 levels must be maintained within specific ranges for apples, bananas, and other produce. VentPlus provides reliable carbon dioxide monitoring for: Cold storage facilities and reefer warehouses Fruit ripening chambers (banana, mango, apple) Controlled atmosphere (CA) storage rooms Dry ice and CO2 cylinder storage areas Breweries, dairy plants and food processing units Basements, parking garages and other confined indoor spaces 12. Basement & Parking Ventilation Residential and commercial basements, server rooms, and underground parking areas accumulate CO2 from human occupancy and vehicle exhaust. VentPlus continuously monitors carbon dioxide and triggers exhaust ventilation automatically to maintain safe air quality. Brief Technical Specifications of VentPlus CO2 Controller CO₂ Measurement Range 400 – 5000 ppm Sensor Type NDIR (Non-Dispersive Infrared) CO2 sensor Accuracy ±50 ppm or ±5% of reading Response Time < 30 seconds Output Control Relay output for fan / CO2 cylinder control Power Supply 230V AC ±15%, 50 Hz Display 128×64 backlit graphic LCD (real-time CO2, temperature, humidity) Operating Temp 0°C to 50°C Humidity Range 0 – 95% RH (non-condensing) Installation Plug & Play (no electrician required) Why VentPlus CO₂ Monitor & Controller is Better Feature VentPlus Typical Plug & Play (no electrician) ✅ ❌ Dual Use (Humans + Plants/Mushrooms) ✅ ❌ NDIR Sensor (Industrial Grade) ✅ ⚠️ Some Optimized for Indian Voltage & Conditions ✅ ❌ Automatic Ventilation Control ✅ ⚠️ Limited CO2 + Temperature + Humidity Display ✅ ❌ Made in India / Local Support ✅ ❌ Suitable for Mushroom Farms & Greenhouses ✅ ⚠️ Limited .comparison-table { width: 100%; border-collapse: collapse; table-layout: fixed; /* Forces equal-ish columns */ word-wrap: break-word; } .comparison-table th:nth-child(1), .comparison-table td:nth-child(1) { width: 60%; } .comparison-table th:nth-child(2), .comparison-table td:nth-child(2) { width: 20%; text-align: center; } .comparison-table th:nth-child(3), .comparison-table td:nth-child(3) { width: 20%; text-align: center; } @media (max-width: 600px) { .comparison-table { font-size: 13px; } .comparison-table th, .comparison-table td { padding: 8px 6px; } } Who Should Buy this CO2 Monitor & Controller? Office & Facility Managers Improving employee productivity, reducing absenteeism, and reducing AC over-ventilation costs. HR & Workplace Wellness Heads Building a measurable healthy-workplace certification for employer branding. Mushroom Farmers Oyster, button, milky, shiitake — control CO2 at every growth stage for premium yield. Greenhouse & Polyhouse Owners Maintain enriched CO2 (800–1500 ppm) for 20–40% higher yield. Hydroponic & Indoor Farmers Plug-and-play CO2 control for grow rooms, grow tents and vertical farms. School & College Administrators Show parents you care about children’s air, cognition and learning outcomes. Hospital & Clinic Administrators Healthier waiting rooms, reduced infection risk, post-COVID compliance. Hotel, Restaurant & Banquet Owners Comfortable guest atmosphere in banquet halls, bars, restaurants and lounges. Gym & Fitness Studio Owners Safer workouts, better performance, no more stuffy yoga rooms. Defense & Army Installations Reliable CO2 monitoring in bunkers, barracks and confined operational spaces. Cold Storage & Food Warehouses Worker safety and controlled-atmosphere storage compliance. Homeowners Healthy bedrooms, basements and sealed apartments — better sleep, better mornings. 📄 Download Product User Manual (PDF) Frequently Asked Questions about VentPlus CO2 Monitor & Controller What is a safe CO2 level for offices and homes? According to ASHRAE Standard 62.1 and WHO indoor air quality guidelines, CO2 levels should ideally be kept between 600 and 1,000 ppm. Levels above 1,500 ppm indicate poor ventilation and cause headaches, fatigue and reduced cognitive performance. Can the VentPlus CO2 controller be used for mushroom farming? Yes. VentPlus is widely used in mushroom farms to control CO2 levels during pinning and fruiting. The controller switches exhaust fans ON when CO2 crosses the upper limit (typically 800–1,500 ppm depending on species and stage) and OFF when levels drop — ensuring proper pinhead formation and cap quality for oyster, button, milky and shiitake mushrooms. Can VentPlus be used in greenhouses and hydroponic grow rooms? Yes. For greenhouses, polyhouses and hydroponic setups, VentPlus can be configured to maintain enriched CO2 levels (typically 800–1,500 ppm) to maximize photosynthesis and crop yield. It controls a CO2 generator, propane burner, or compressed CO2 cylinder solenoid. Suitable for grow rooms, grow tents and indoor cultivation. Does the CO2 monitor require professional installation? No. The VentPlus is designed for easy plug-and-play setup. Simply plug your exhaust or fresh-air fan into the device’s AC socket, set your ON and OFF thresholds using the front-panel buttons, and it begins working immediately. What is the price of the VentPlus CO2 monitor and controller in India? For pricing in India, please call +91-9917080700 or use the Contact Us page to request a quotation. We offer competitive pricing for single units as well as bulk orders for offices, schools, hospitals, mushroom farms and greenhouses. What type of CO2 sensor does VentPlus use? VentPlus uses an industrial-grade NDIR (Non-Dispersive Infrared) CO2 sensor with a measurement range of 400 to 5,000 ppm and accuracy of ±50 ppm or ±5% of reading. NDIR is the most reliable carbon dioxide sensing technology and is recommended by ASHRAE for demand-controlled ventilation applications. Is the CO2 controller suitable for 24/7 continuous operation? Yes. VentPlus is built with high-quality NDIR sensors and an industrial-grade 32-bit ARM microcontroller for reliable 24×7 continuous monitoring in offices, hospitals, mushroom farms, greenhouses and other environments — without manual intervention. Can I change the CO2 ON and OFF trigger levels myself? Yes. The device features user-friendly buttons (ESC, INCR, DECR, SEL/NEXT) and a large 128×64 backlit LCD screen. You can customize the Fan ON level (default 1,000 ppm), Fan OFF level (default 800 ppm), and beeper alert level (default 1,500 ppm) to suit indoor occupancy or agricultural needs. Does VentPlus also measure temperature and humidity? Yes. In addition to CO2, VentPlus displays real-time ambient temperature (±0.2°C accuracy) and relative humidity (±2% accuracy). This makes it especially useful for mushroom farms, greenhouses, hydroponic grow rooms and hospitals where multiple environmental parameters matter. Can VentPlus control a CO2 cylinder or CO2 generator (for greenhouses)? Yes. The relay output can drive either an exhaust fan (to lower CO2) or a CO2 cylinder solenoid / CO2 generator (to raise CO2 for plant photosynthesis in greenhouses, polyhouses and hydroponic grow rooms). Upgrade Your Air Quality Today Don’t let poor air quality affect your health, your crop yield, or your business performance. Get the VentPlus CO2 Monitor & Controller designed and built for Indian conditions. 📞 Direct Support: +91-9917080700 Contact Us for a Quote Full Technical Specifications S.No Item Technical Description 1 Measured Parameters • CO2 Concentration Level • Ambient Temperature • Relative Humidity 2 Measurement Accuracy CO2: 400–5000 ppm | ±(50 ppm + 5% reading)* Temperature: 0–50°C | ±0.2°C Humidity: 0–95% RH | ±2% (10–90% range) *After 10-minute warm-up period 3 Programmable Settings • Fan ON Level: Default 1000 ppm • Fan OFF Level: Default 800 ppm • Beeper Alert: Default 1500 ppm (Enable/Disable) • LCD Brightness: Default 75% (Auto-off at night) 4 Input Power 230V AC ± 15% | 50 Hz 5 Output Control Relay-operated AC supply for Fresh Air / Exhaust Fan or CO2 cylinder solenoid (Max. 5A current) 6 Display Type 128×64 pixel backlit graphic LCD (8 rows of parameters/settings) 7 User Interface 4-Key Industrial Keypad: ESC, INCR, DECR, SEL/NEXT 8 LED Status Visual indicator for Fan / Exhaust relay activation 9 Operational Limits Temperature: -5 to 50°C Humidity: 0 to 95% RH (Non-condensing) 10 Processing Power Advanced 32-bit ARM-based Microcontroller .tech-specs-table { width: 100%; border-collapse: collapse; table-layout: fixed; word-wrap: break-word; overflow-wrap: break-word; margin: 16px 0 24px; } .tech-specs-table th, .tech-specs-table td { padding: 8px 10px; vertical-align: top; border-bottom: 1px solid #e0e6ed; } /* Column widths */ .tech-specs-table th:nth-child(1), .tech-specs-table td:nth-child(1) { width: 12%; text-align: center; } .tech-specs-table th:nth-child(2), .tech-specs-table td:nth-child(2) { width: 32%; } .tech-specs-table th:nth-child(3), .tech-specs-table td:nth-child(3) { width: 56%; } /* Mobile: minimal padding, smaller font, narrower S.No column */ @media (max-width: 600px) { .tech-specs-table { font-size: 11.5px; line-height: 1.45; } .tech-specs-table th, .tech-specs-table td { padding: 5px 4px; } .tech-specs-table th:nth-child(1), .tech-specs-table td:nth-child(1) { width: 9%; } .tech-specs-table th:nth-child(2), .tech-specs-table td:nth-child(2) { width: 30%; } .tech-specs-table th:nth-child(3), .tech-specs-table td:nth-child(3) { width: 61%; } } /* Even smaller phones (320–360px wide) */ @media (max-width: 380px) { .tech-specs-table { font-size: 10.5px; } .tech-specs-table th, .tech-specs-table td { padding: 4px 3px; } }

AI Readiness

Good foundation, but some important product data is still missing.

67%