The JB is a DC circuit breaker dedicated to multi string photovoltaic installations. This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits. Combined with a switch , the JB will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules. IEC 60947-2, EN60947-2, GB 14048.2 DC Circuit Breaker - Miniature Circuit Breakers for DC and Solar Generation The JB is a DC circuit breaker dedicated to multi string photovoltaic installations. This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits. Combined with a switch , the JB will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules. It can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter. Since a fault current can flow in the reverse direction to the operating current, the JB can detect and protect against any bidirectional current. To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the JB with: a residual current device at the AC end a fault passage detector (insulation monitoring device) at the DC end an earth protection circuit breaker at the DC end NOTES In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault). JB is not polarity sensitive: (+) and (-) wires can be inverted without any risk. Meaning and Classification Models Main Characteristics Operating Voltage (Ue) 1P=250 V DC, 2P=500 V DC 3P=750 V DC, 4P=1000 V DC Rated insulation voltage (Ui) 1,000 VDC Breaking capacity (Icu) 10 kA Impulse voltage (Uimp) 4 kA Electrical connection By the bottom for In and Out Number of poles 1P, 2P, 3P, 4P Standards IEC 60947-2 EN 60947-2 Technical Data Position contact indication – suitability for isolation according to IEC/EN 60947-2 standard. The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. Pre-wired product: Input / Output on the same side. Rated service breaking capacity (Ics) 100 % of the Icu Endurance (O-C) Electrical 1,500 cycles (where L/R=2 ms) Mechanical 20, 000 cycles Mechanical 20, 000 cycles Degree of pollution 2 Category A (no delay in accordance with IEC / EN 60947-2 standards) Degree of protection (IEC 60529) IP40 Tropicalisation Relative humidity: 95 % at 55°C in accordance with IEC 60068-2 and GB 14048.2 standards Temperature Operating -25°C to 70 °C Storage -40°C to 85°C Curve Wiring Diagram Installation Dimensions (mm) Weight (g) Circuit breaker Type 1P 2P 3P 4P Weight (g) 120 240 360 480 Connection
Specifications
- Poles
- 1P
- Voltage
- 250VDC
- Current
- 1A, 2A, 3A, 4A, 6A, 10A, 15A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Variants (14)
- 1P / 250VDC / 1A — 5.46 USD — In stock
- 1P / 250VDC / 2A — 5.46 USD — In stock
- 1P / 250VDC / 3A — 5.46 USD — In stock
- 1P / 250VDC / 4A — 5.46 USD — In stock
- 1P / 250VDC / 6A — 5.46 USD — In stock
- 1P / 250VDC / 10A — 5.46 USD — In stock
- 1P / 250VDC / 15A — 5.46 USD — In stock
- 1P / 250VDC / 16A — 5.46 USD — In stock
- 1P / 250VDC / 20A — 5.46 USD — In stock
- 1P / 250VDC / 25A — 5.46 USD — In stock
- 1P / 250VDC / 32A — 5.46 USD — In stock
- 1P / 250VDC / 40A — 5.46 USD — In stock
- 1P / 250VDC / 50A — 5.46 USD — In stock
- 1P / 250VDC / 63A — 5.46 USD — In stock