WiFi Snow Melting Controller for Roof & Driveway De-Icing

WiFi Snow Melting Controller for Roof & Driveway De-Icing

Brand: YeloDeer
SKU: EFC1-G
19.99 USD In stock Buy at Merchant

Overview WiFi Snow Melting Controller System for Roof, Gutter, Driveway, and Walkway De-Icing The YeloDeer EFC1 is an automatic snow melting controller designed to operate compatible heating cable systems based on both outdoor temperature and moisture conditions. Choose the Ground Sensor Kit for paved surfaces or the Roof Sensor Kit for roof and gutter de-icing applications. The controller supports 120V and 240V systems, WiFi monitoring through the Smart Life app, and automatic or forced heating control. The heating cable itself provides the snow-melting heat and is not included with the controller sensor kits. Quick Fit Snapshot Ground or Roof Sensor Choose EFS-G for driveways and paved surfaces, or EFS-R for roofs, gutters, and downspouts. 120V / 240V Compatible EFC1 accepts 85–265V AC, 50/60Hz power for compatible North American snow melting systems. 16A Max Relay Maximum controller relay current is 16A. For continuous operation, keeping the connected load at or below 11A is recommended. Temperature + Moisture Automatic heating operates only when the selected temperature conditions and moisture detection requirements are both satisfied. Key Benefits Automatic Snow & Ice Control Helps operate compatible heating cables only when cold and wet conditions indicate de-icing may be needed. Application-Specific Sensors Separate ground and roof sensor designs allow the system to match the way meltwater is detected in different locations. WiFi Remote Monitoring Connect through a 2.4 GHz WiFi network and the Smart Life app for compatible remote monitoring and control functions. Automatic or Forced Heating Use automatic dual-sensor operation for normal winter control or activate forced heating when temporary manual operation is required. Choose the Right SKU Weatherproof Enclosure Only IP65 Enclosure DIN Rail Housing Outdoor Controller Protection Choose this option when you need a weatherproof enclosure for an EFC1 controller installation. This SKU is the enclosure only and does not include the EFC1 controller or moisture sensors. Roof Sensor Kit — EFC1 + EFS-R Roof Edges Gutters Downspouts Choose the EFS-R roof moisture sensor for roof and gutter de-icing systems where meltwater can reach the sensor surface. Ground Sensor Kit — EFC1 + EFS-G Driveways Walkways Porches & Ramps Choose the EFS-G ground moisture sensor for paved snow melting areas. The sensor is designed for horizontal, flush installation in the protected surface. Suitable For Ground Snow Melting Driveways Walkways Sidewalks Ramps Porches Loading Docks Roof & Drainage De-Icing Roof Edges Gutters Downspouts Roof Drainage Areas Important Before Ordering Confirm the SKU, electrical load, installation location, and heating cable system before ordering. The Ground Sensor Kit and Roof Sensor Kit use the same EFC1 controller but different moisture sensors. Choose EFS-G for ground applications and EFS-R for roof or gutter applications. The Weatherproof Enclosure SKU is the enclosure only. It does not replace the controller or sensor kit. Heating cable is not included with the controller sensor kits. The EFC1 controls a compatible external snow melting or de-icing heating system. The EFC1 controller is IP20. Install it indoors or inside a suitable weatherproof electrical enclosure when used in an outdoor installation. Maximum relay current is 16A. For long-term continuous operation, keeping the connected load at or below 11A is recommended. For loads above 16A, 3-phase systems, or systems above 265V, use a properly rated external AC contactor rather than routing the heating load directly through the controller. The controller supports 85–265V AC, 50/60Hz. Confirm the heating cable voltage and circuit configuration before wiring. WiFi control requires a stable 2.4 GHz network. A non-metallic enclosure is preferred when possible because a fully enclosed metal box may weaken the WiFi signal. Electrical Safety This controller must be installed and wired by a qualified electrician in accordance with applicable electrical requirements. Disconnect power before installation, wiring, inspection, or maintenance. Appropriate circuit breaker and GFCI/leakage protection are strongly recommended. The heating cable ground conductor must be connected to the mains grounding system. Do not install the controller near flammable materials, heat sources, or in hazardous or explosive atmospheres. Choose Ground or Roof Sensor Kit Confirm 120V or 240V System Calculate Total Heating Load Keep Direct Relay Load Within Rating Plan Weatherproof Controller Protection Provide Required Circuit Protection Confirm Sensor Installation Location Confirm Stable 2.4 GHz WiFi if App Control Is Needed Related Roof De-Icing Products Building a roof or gutter de-icing system? Explore YeloDeer Roof & Gutter De-Icing Cables. Applications Ground Sensor Applications — EFS-G The EFS-G Ground Sensor Kit is designed for outdoor paved areas where the moisture sensor can be installed horizontally in the snow melting surface and exposed to representative meltwater conditions. Residential Ground Areas Driveways Walkways Sidewalks Porches Access & Traffic Areas Ramps Stairs Loading Docks Outdoor Paved Areas Roof Sensor Applications — EFS-R The EFS-R Roof Sensor Kit is designed for roof and drainage applications where melting snow or ice water can reach the moisture-sensing surface. Roof De-Icing Roof Edges Ice-Prone Areas Roof Drainage Paths Gutter Freeze Protection Gutters Downspouts Meltwater Paths Who This System Is For Homeowners For automatic control of compatible residential driveway, walkway, roof, and gutter snow melting systems. Property Managers For seasonal snow and ice control around residential, rental, and small commercial properties. Contractors & Electricians For DIN-rail snow melting control systems requiring temperature and moisture-based activation. DIY Project Planning Suitable for experienced users planning a snow melting system, while electrical installation and wiring must be completed by a qualified electrician. Applications to Avoid Recommended Use the controller with a properly designed outdoor snow melting or roof de-icing heating system where temperature and meltwater conditions can be monitored correctly. Do Not Use Do not install the controller in hazardous or explosive atmospheres, near flammable materials or heat sources, or with electrical loads outside the controller rating unless a properly rated external contactor is used. The system detects water, not snow directly. Snow and ice are poor electrical conductors, so the moisture sensor uses its built-in heater to help melt snow or ice on the sensor surface before moisture is detected. Specifications EFC1 Controller Specifications Model EFC1 Product Type WiFi snow melting and de-icing controller Input Voltage 85–265V AC, 50/60Hz Typical North American Systems 120V or 240V AC Maximum Relay Current 16A Recommended Continuous Load 11A or less for long-term continuous operation Standby Power 2W Relay Type AC-1 Mounting 35 mm DIN rail Controller IP Rating IP20 Maximum Terminal Wire Size 2.5 mm² / 13 AWG Controller Dimensions 3.54 × 2.09 × 2.56 in / 90 × 53 × 65 mm Ambient Temperature 32–113°F / 0–45°C Storage Temperature 14–122°F / -10–50°C Air Temperature Sensor NTC, 10 kΩ at 77°F / 25°C Air Sensor Cable Length 9.8 ft / 3 m Control Logic Outdoor temperature + moisture detection WiFi 2.4 GHz WiFi; Smart Life app compatible Operating Modes Automatic Mode and Forced Heating Mode Warranty 1-year limited warranty for product quality-related issues Moisture Sensor Specifications Specification EFS-G Ground Sensor EFS-R Roof Sensor Recommended Application Driveways, walkways, ramps, porches, paved snow melting areas Roof edges, gutters, downspouts, roof drainage areas Sensor Cable Length 32.8 ft / 10 m 32.8 ft / 10 m Temperature Sensor NTC, 10 kΩ at 77°F / 25°C NTC, 10 kΩ at 77°F / 25°C Internal Sensor Heater 5W 5W IP Rating IP68 IP68 Ambient Temperature -58–158°F / -50–70°C -58–158°F / -50–70°C Measured Temperature Range -22–167°F / -30–75°C -22–167°F / -30–75°C Operating Temperature -58–158°F / -50–70°C -58–158°F / -50–70°C Dimensions 2.36 × 2.36 × 1.42 in / 60 × 60 × 36 mm 4.72 × 1.18 × 0.59 in / 120 × 30 × 15 mm Weight 26.74 oz / 758 g 16.68 oz / 473 g About the 5W sensor heater: The internal heater inside the EFS-G and EFS-R moisture sensors is used only to melt snow or ice on the sensor surface so moisture can be detected. It is not designed to melt snow across the driveway, roof, gutter, or other protected area. Advanced Control Functions Function Default Setting Range F0 — Temperature Unit °F °F / °C F1 — Drying Delay Time 2 hours 0.5–9 hours F2 — Air Temperature Calibration 0°F / 0°C ±9°F / ±5°C F3 — Moisture Detection Threshold 200 10–990 F4 — Maximum Heating Alarm Time 36 hours 1–240 hours F5 — Temperature Hysteresis 1°F / 1°C 1–18°F / 0.1–10°C F6 — Total Heating Hours View only View only F7 — Heating Cycle Counter View only View only F8 — Software Version View only View only F9 — Factory Reset No No / Reset Weatherproof Enclosure SKU Product Type Weatherproof DIN rail controller enclosure IP Rating IP65 Primary Use Protecting the EFC1 controller in suitable outdoor installations Cover Transparent access window Included Controller No — enclosure SKU only Included Moisture Sensor No — enclosure SKU only Installation Installation Overview The EFC1 is a DIN-rail electrical controller and must be installed and wired by a qualified electrician. The following information is intended as a pre-installation overview rather than a replacement for the complete instruction manual. Select the correct EFS-G Ground Sensor or EFS-R Roof Sensor kit for the application. Confirm supply voltage, heating cable voltage, total current, circuit protection, and whether an external contactor is required. Install the EFC1 indoors or inside a suitable weatherproof electrical enclosure. Install the air temperature sensor outdoors in a shaded location away from direct sunlight, rain, and snow. Install the selected moisture sensor where representative meltwater can reach the sensor surface. Complete power, load, grounding, and sensor wiring according to the wiring diagram in the instruction manual. Restore power, configure the operating temperature range and moisture settings, and test system operation before winter use. Controller Installation DIN Rail Mounting Mount the EFC1 on a standard 35 mm DIN rail. Protect the Controller The EFC1 is IP20 and must be installed indoors or inside a suitable weatherproof electrical enclosure. Mount Above Ground The manual specifies installing the controller more than 19.7 in / 0.5 m above ground. Recommended Installation Temperature Install in an environment approximately 23–95°F / -5–35°C when possible. Add Circuit Protection Install appropriate circuit breaker and leakage/GFCI protection in series with the controller. Ground the Heating System The heating cable ground conductor must be connected to the mains grounding system. Air Temperature Sensor Placement Recommended Install the air temperature sensor in a shaded outdoor location protected from direct sunlight, rain, and snow. Under the eaves is recommended when available. Avoid Do not route the air sensor cable alongside power wiring unless appropriate shielding is used, because electrical interference can affect temperature readings. EFS-G Ground Sensor Installation Install Horizontally The moisture sensor must be placed horizontally with its sensing surface facing upward, even when the surrounding paved area is sloped. Keep the Top Flush Install on a solid concrete base with the sensor surface flush with the finished ground surface. Position Between Heating Cables Keep the sensor at least 0.8 in / 2 cm away from each adjacent heating cable. Stay Away From the Edge Keep the sensor at least approximately 3.3 ft / 1 m from the edge of the snow melting area. Choose a Representative Wet Area Install in a low, wet, shaded area where meltwater conditions represent the snow melting surface. Seal Around the Sensor Seal gaps so meltwater flows over the sensing surface rather than draining into gaps around the sensor. For asphalt installations, replace the normal protective conduit with metal conduit and do not install the EFS-G sensor before paving. Protect sensor wiring and follow the complete installation instructions. EFS-R Roof Sensor Placement Install the EFS-R in a roof, gutter, or drainage location where melting snow or ice water can reliably reach the moisture-sensing surface. Keep the sensor secured, unobstructed, and accessible for seasonal inspection and cleaning. Load Wiring The EFC1 LOAD terminals function as switching contacts and do not independently supply power to the heating cable. Follow the 120V or 240V wiring diagram supplied with the controller. For loads above 16A, 3-phase systems, or supply voltages above 265V, use a properly rated external AC contactor. WiFi Installation Notes 2.4 GHz WiFi Only The controller requires a stable 2.4 GHz WiFi network for Smart Life app connectivity. Check Signal Before Final Mounting Confirm WiFi performance at the controller location before completing the enclosure installation. Prefer Non-Metallic Enclosures A plastic or other non-metallic enclosure is recommended when possible for more reliable WiFi communication. Avoid Fully Enclosed Metal Boxes A metal enclosure may weaken or block WiFi. Verify signal strength before final installation if a metal enclosure must be used. For additional installation resources, visit the YeloDeer Installation Guide. FAQ Which SKU should I choose? Choose the EFC1 + EFS-G Ground Sensor Kit for driveways, walkways, sidewalks, porches, ramps, loading docks, and similar paved snow melting surfaces. Choose the EFC1 + EFS-R Roof Sensor Kit for roof edges, gutters, downspouts, and roof drainage de-icing systems. Choose the Weatherproof Enclosure only when you need an enclosure for the controller. The enclosure SKU does not include the EFC1 controller or moisture sensor. What is the difference between the EFS-G and EFS-R sensors? Both work with the same EFC1 controller and use moisture detection with an internal 5W sensor heater. The EFS-G is a round ground sensor designed for horizontal, flush installation in paved snow melting surfaces. The EFS-R is a lower-profile roof sensor designed for roof, gutter, and downspout applications. Does the controller detect snow directly? No. The system detects water on the moisture sensor surface rather than snow itself. Because snow and ice are poor electrical conductors, the moisture sensor uses its built-in heater to help melt snow or ice on the sensing surface. Once water is detected and the outdoor temperature is within the selected operating range, automatic heating can begin. Why might the system not start immediately when snowfall begins? The sensor may need time to melt snow or ice on its surface into detectable water. This is normal for the moisture-detection method used by the system. The controller also operates only when the outdoor temperature is within the configured operating range. Can I use the EFC1 with both 120V and 240V snow melting systems? Yes. The EFC1 accepts 85–265V AC, 50/60Hz input and can be wired for compatible 120V or 240V systems. Always confirm the heating cable voltage, circuit configuration, wiring method, grounding, and load before installation. Can the controller power my heating cable directly? The controller relay is rated for a maximum of 16A. For long-term continuous operation, keeping the direct connected load at or below 11A is recommended. For loads above 16A, 3-phase systems, or systems above 265V, the EFC1 should control a properly rated external AC contactor rather than carry the full heating load. Can the EFC1 controller be installed outdoors? The EFC1 controller itself is rated IP20 and should not be directly exposed to outdoor weather. Install it indoors or inside a suitable weatherproof electrical enclosure. For WiFi installations, a non-metallic enclosure is preferred when possible because metal can reduce WiFi signal strength. What WiFi network does the controller require? The EFC1 uses a 2.4 GHz WiFi network and supports remote control through the Smart Life app. Check WiFi signal strength at the final installation location before completing the enclosure installation. Guides How Automatic Mode Works 1. Monitor Outdoor Temperature The controller continuously checks outdoor air temperature. 2. Monitor Moisture When temperature enters the selected operating range, the system begins monitoring the moisture sensor. 3. Start Heating When water is detected while temperature conditions are satisfied, the controller activates the connected heating system. 4. Continue Through Drying Delay After moisture is no longer detected, heating continues for the preset drying-delay period before shutting off automatically. Temperature Range Logic Above Upper Limit Conditions are considered too warm for normal snow or ice risk, so moisture monitoring does not operate. Between Upper & Lower Limits The system monitors moisture and can activate heating when water is detected. Below Lower Limit The controller stops automatic moisture monitoring because conditions may be too cold for effective melting or drainage. Example from the manual: with an upper limit of 41°F / 5°C and a lower limit of 14°F / -10°C, moisture monitoring operates while outdoor temperature is between those limits. Forced Heating Mode Forced Heating Mode allows the connected heating system to operate continuously for a selected period without checking the normal temperature and moisture activation conditions. Typical Uses Emergency De-Icing System Testing Pre-Heating Drying Wet Surfaces Forced Heating bypasses the normal automatic detection logic. Use it only when necessary and monitor the connected heating system appropriately. Before Each Winter Season Inspect All Wiring Connections Inspect Heating Cable for Visible Damage Check GFCI / Leakage Protection Clean the Moisture Sensor Surface Remove Leaves, Stones, Dirt, and Debris Confirm Meltwater Can Drain Away Check Sensor Placement Run a Short Test Before the First Snowfall Sensor Care Keep the Surface Clean Leaves, dirt, stones, ice blockage, or other debris can interfere with moisture detection and may trigger abnormal-operation alarms. Maintain Drainage Water must be able to reach and leave the sensing surface normally. Standing water or poor drainage can affect system operation. Inspect After Severe Weather Check the sensor and surrounding area after heavy snowfall, ice accumulation, maintenance work, or unusual drainage conditions. Check Before Replacing Parts If abnormal moisture detection occurs, first inspect sensor cleanliness, drainage, wiring, and physical condition. System Planning Checklist Select EFS-G for Ground or EFS-R for Roof Confirm Heating Cable Voltage Calculate Total System Current Determine Whether a Contactor Is Required Plan Controller Enclosure Location Plan Air Temperature Sensor Location Plan Moisture Sensor Location Provide Circuit Breaker and Ground-Fault Protection Verify Grounding Check 2.4 GHz WiFi Signal if App Control Is Needed Test Automatic Operation Inspect the System Before Each Winter Season Need Installation Help? See the YeloDeer Installation Guide for additional installation resources. For project-specific questions, contact yelodeer@yelodeer.com with your supply voltage, heating cable specifications, total load, application type, wiring plan, and installation photos.

Specifications
Configuration
Ground Sensor Kit – EFC1 + EFS-G, Roof Sensor Kit – EFC1 + EFS-R, Weatherproof Enclosure Only
Variants (3)
  • Ground Sensor Kit – EFC1 + EFS-G — 341.99 USD — In stock
  • Roof Sensor Kit – EFC1 + EFS-R — 341.99 USD — Out of stock
  • Weatherproof Enclosure Only — 19.99 USD — In stock

How AI sees this product

The more complete this product's details, the more confidently AI assistants can understand and recommend it.

89%