BIONOTE Anigen Rapid FPV Ag – Feline Panleukopenia Virus Antigen Test – 10 Tests

BIONOTE Anigen Rapid FPV Ag – Feline Panleukopenia Virus Antigen Test – 10 Tests

Brand: iVet Medical
Out of stock View at Merchant

Description The BIONOTE Anigen Rapid FPV Ag Test Kit is a rapid veterinary diagnostic test designed to detect Feline Panleukopenia Virus (FPV) antigen in fecal specimens from cats. FPV is the virus associated with feline panleukopenia, a highly contagious disease that can cause gastrointestinal and systemic illness, particularly in susceptible cats and kittens. The test uses an immunochromatographic assay to provide a qualitative result through a simple visual test format. BIONOTE lists the testing time as approximately 10 minutes. Key Features Rapid detection of Feline Panleukopenia Virus antigen Designed specifically for cats Uses feline feces as the specimen Immunochromatographic assay Results in approximately 10 minutes Simple visual interpretation No additional analyzer required 10 Tests/Kit Storage at 2–30°C Suitable for veterinary diagnostic screening What Does It Detect? Target: Feline Panleukopenia Virus (FPV) antigen Disease: Feline panleukopenia Animal: Cat Specimen: Feces Test type: Qualitative antigen detection Product Specifications Specification Details Brand BIONOTE Product Name Anigen Rapid FPV Ag Product No. RG1203DD Target Feline Panleukopenia Virus (FPV) Test Type Antigen detection Method Immunochromatographic assay Animal Cat Specimen Feces Testing Time Approximately 10 minutes Pack Size 10 Tests/Kit Storage 2–30°C Intended Use Veterinary diagnostic use Sample Collection The recommended specimen for the Rapid FPV Ag test is feline feces. BIONOTE specifically states that blood or serum is not the appropriate specimen for this FPV antigen kit. A fecal sample may be collected directly from feces or from the rectum using the supplied collection swab. General Test Procedure Collect an appropriate amount of feline fecal specimen using the supplied swab. Insert the swab into the sample dilution tube. Mix the specimen thoroughly with the diluent. Remove the swab while squeezing it against the tube wall to recover the sample. Using the supplied disposable dropper, transfer the prepared sample to the test device. Allow the sample to migrate through the test window. Read the result at approximately 10 minutes. Interpret the result according to the manufacturer's current Instructions for Use. The exact sample preparation and operating procedure should always follow the IFU supplied with the product. Result Interpretation Negative Only the Control (C) line appears. This indicates that the test did not detect FPV antigen in the specimen at the applicable detection level. Positive Both the Control (C) and Test (T) lines appear. This indicates that Feline Panleukopenia Virus antigen has been detected. Invalid If the required control line does not appear, the result is invalid and the test should be repeated with a new device. Important Diagnostic Information The Rapid FPV Ag test is intended as an initial screening/diagnostic aid. BIONOTE states that test results should not be used alone to establish a final diagnosis; clinical signs and other laboratory findings should also be considered by a veterinarian. Vaccination Consideration Recent vaccination can affect FPV antigen test interpretation. BIONOTE notes that feline panleukopenia vaccines may result in detectable virus shedding and that test results should therefore be interpreted carefully in recently vaccinated cats. Kit Contents For the 10 Tests/Kit configuration, the kit includes the components required to perform the tests, including: 10 × Rapid FPV Ag test devices Sample dilution tubes / assay diluent Disposable specimen swabs Disposable droppers Instructions for Use Always verify the physical package and current IFU for the exact component quantities supplied with your lot. Storage & Handling Store at 2–30°C Do not freeze Keep the test components protected from moisture Remove the test device from its foil pouch immediately before use Do not use damaged test devices or compromised packaging Do not use after the expiration date Handle fecal specimens using appropriate protective measures Follow the manufacturer's current Instructions for Use BIONOTE specifies storage at 2–30°C.

Variants (1)
  • Default Title — 0.00 AED — Out of stock

How AI sees this product

The more complete this product's details, the more confidently AI assistants can understand and recommend it.

58%