UGREEN Cat 8 S/FTP Pure Copper Ethernet Cable Reel, 305m, Yellow (80426)
UGREEN · SKU 80426UGREEN Cat 8 S/FTP Pure Copper Ethernet Cable Reel, 305m, Yellow The UGREEN NW151 80426 is a 305 m reel of yellow Cat 8 S/FTP copper Ethernet cable for building custom-length network runs. Its solid copper conductors and shielded construction suit structured cabling projects where the installer selects, terminates and tests each cable run. The reel supplies cable for multiple runs; 305 m is the supplied quantity, not a promised single-link reach. Key features 305 m supply reel Cut cable to suit measured routes and minimise unnecessary slack across a multi-run installation.Pure copper conductors 22 AWG solid conductors use approximately 0.62 mm copper cores.S/FTP shielding An overall braid and foil around the twisted pairs help control interference within a correctly installed shielded link.Yellow jacket A distinctive outer colour helps identify this cable within mixed network cabling. A practical guide to choosing and using it Build measured runs from one reel Bulk cable lets an installer cut each run to the planned route. It is useful when several network points need different lengths and standard patch leads would leave unnecessary slack. Measure the cable path, allow working space at the termination points and label each run as it is installed. The reel is a supply for multiple links, rather than one ready-to-connect lead.Match the termination hardware The solid 22 AWG conductors and shielded construction need suitable connectors, jacks or patch-panel hardware. Check that the chosen hardware accepts the conductor gauge and cable diameter and supports the intended shielding arrangement. A connector’s familiar RJ45 shape does not guarantee that it will terminate every cable construction properly. Follow the termination hardware instructions and test the finished link.Think about the complete network link Cable category is one part of network performance. The ports at both ends, connectors, patch panels, patch leads, route length and workmanship all affect the result. A higher cable category cannot make a slower network port run faster. Plan for the actual equipment and target link performance, then verify the installed channel rather than relying only on the reel specification.Make future changes easier Keep a record of where each cable starts and ends, and leave manageable service slack without crushing the jacket or creating tight bends. The yellow outer jacket helps distinguish the runs from other cable groups. Route and secure the cable for the installation environment, maintaining access to termination points so a later network change does not require disturbing neighbouring connections.Where it fits Custom network runs Prepare measured cable lengths between compatible structured cabling points.Cabinet projects Supply multiple terminated links for a planned server-room or network installation. Will it work with your setup? Requires separately selected compatible network connectors, jacks or patch panels. Network performance depends on run length, termination quality and every component in the complete link. Setup and everyday use Measure each route and allow sensible slack at termination points. Select connectors or jacks compatible with the cable diameter, conductor gauge, solid cores and shielding. Terminate the pairs consistently and maintain shielding continuity as required by the installation. Test each finished link with appropriate equipment before putting it into service. A closer look Before you buy This is bulk cable and requires termination before use. The 305 m reel length must not be treated as a 305 m high-speed Ethernet channel rating. Choose installation-rated cable for the required environment; check fire, outdoor and in-wall requirements before routing. Technical specifications Brand / SKU UGREEN 80426 Model NW151 Cable category Cat 8 Shielding S/FTP Supplied length 305 m reel Conductors Pure copper, solid Gauge 22 AWG Conductor diameter Approximately 0.62 mm Colour Yellow Inside the box 1 × 305 m reel of UGREEN 80426 Ethernet cableFrequently asked questions Is this a finished Ethernet cable with RJ45 plugs?No. It is a 305 m reel of bulk Ethernet cable for cutting and terminating to suit an installation. Connectors or jacks are selected separately for the cable construction and planned link. If you only need to connect a nearby router and computer immediately, choose an appropriately specified pre-terminated patch lead instead of a reel that requires installation work.Can I use all 305 m as a single network connection?The 305 m figure describes the quantity supplied on the reel. It is not a promise that a single 305 m Ethernet link will operate at the advertised category’s highest speed. Plan each finished run for the intended Ethernet application, equipment and channel-length requirements. Divide the reel into suitable runs and test each completed link.What does S/FTP mean for this cable?It describes shielding with an overall braid and foil around the twisted pairs. That construction is intended to help manage interference in a correctly designed shielded cabling system. Its benefit depends on appropriate termination and installation. Choose compatible shielded hardware and follow the cabling system’s bonding and installation requirements rather than treating shielding as a substitute for correct routing.Will installing this make my internet connection faster?It cannot raise the speed supplied by your internet plan or overcome a slower router, switch or computer port. It is one component of the physical network. A suitable cable installation can support the capabilities of matching equipment, but the actual connection rate and application performance are limited by the complete path and the services being used.How should I choose compatible connectors or wall jacks?Check the hardware’s supported conductor gauge, solid-conductor compatibility, cable diameter and shielding arrangement. Also choose hardware appropriate for the target channel performance. This reel uses 22 AWG solid copper conductors, so a connector intended for a different conductor construction may not be suitable. Follow the hardware manufacturer’s termination instructions and verify the result with a cable tester.Can I run it outdoors or directly through any wall space?Do not assume that a cable is approved for every environment because it is described as Cat 8. The jacket and installation ratings must suit the intended route. This reel is presented for indoor cabling. Check the applicable building, fire and routing requirements before installation, and choose a specifically suitable cable where outdoor exposure or another special environment is involved.Is solid copper cable suitable for a cable that is moved frequently?This reel is primarily useful for planned, terminated cable runs. For a short connection that is unplugged, bent or repositioned frequently, a suitable flexible finished patch lead is often more convenient. Match the cable construction to the job and avoid repeated sharp bending at fixed terminations. The choice of conductor construction matters as well as the cable category.Do I need special setup software?The cable itself does not require software. It needs correctly selected termination hardware and proper physical installation. Once connected, the network devices establish their link according to their own capabilities and configuration. Any network settings, access permissions or troubleshooting still belong to those devices and the network, rather than to a software driver for the cable.Why should each finished run be tested?A continuity or wiring problem can prevent a link from working, while less obvious termination or installation problems can limit performance. Testing checks the work after cutting and terminating the cable. Select a tester appropriate to the level of assurance required; a simple wire-map check and a full performance certification are different tasks with different equipment requirements.What should an installer plan before cutting the reel?Measure the actual cable routes, decide where terminations will be accessible, choose compatible connectors or jacks and allow suitable working slack. Record the identity of each cable run and check the target link requirements. Planning these points first helps avoid pieces that are too short, unnecessary joints and a cabinet full of unlabelled cables after installation.
Variants (1)
- Default Title — 77099.00 INR — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.