Xylem Flygt 40-501098 MiniCAS II 11-Pin Supervision Relay 120VAC

Xylem Flygt 40-501098 MiniCAS II 11-Pin Supervision Relay 120VAC

Brand: Xylem
512.00 USD In stock Buy at Merchant

Xylem Flygt 40-501098 MiniCAS II 11-Pin Supervision Relay 120VAC Product Basic Information: Manufacturer: Flygt / Xylem Flygt Catalog number: 40-501098 Non-hyphenated part number: 40501098 Product family/series: MiniCAS II Product type: Pump supervision relay / monitoring relay Relay type: Temperature and leakage monitoring relay Mounting style: 11-pin socket mount Technical Specifications: Series: MiniCAS II Part number: 40-501098 Supply voltage: 120 VAC Supply voltage tolerance: -15% to +15% Supply frequency: 50/60 Hz Power requirement: 5 VA Operating principle: Current sensing Sensor output voltage: 12 VDC, +/- 5% Normal sensor current range: 3 mA to 22 mA High temperature alarm condition: Less than 3 mA or sensor circuit interruption Leakage alarm condition: Greater than 22 mA or sensor circuit short circuit Leakage alarm delay: 10 seconds Relay contact rating: 5 A at 250 VAC Temperature alarm contact function: Changeover relay contacts Leakage alarm contact function: Changeover relay contacts Reset type for temperature alarm: Manual reset Reset options: External reset push button or supply voltage interruption Leakage alarm reset type: Automatic reset Front indication lamps: Supply, temperature alarm, and leakage alarm Pump communication wiring: 2-wire sensor connection Socket type: Standard 11-pin socket Compatible sensor types: Thermal switches, FLS, FLS10, and CLS sensors Operating temperature range: -25 to +60 °C Product Features: Monitors common submersible pump threats including high stator temperature and leakage Supports thermal switch monitoring for stator overtemperature detection Supports FLS leakage sensor monitoring for liquid detection in stator housing or junction box Supports FLS10 leakage sensor monitoring for inspection chamber applications Supports CLS water-in-oil sensor monitoring for oil chamber applications Three front indication lamps for supply, temperature alarm, and leakage alarm status Uses two-wire communication between the pump sensor circuit and MiniCAS II relay Can stop the pump or provide alarm indication depending on control wiring configuration COUNTRY OF ORIGIN INFORMATION IS INCLUDED WHERE AVAILABLE. * Buyer is responsible for all customs duties, tariffs, brokerage fees, local levies, taxes, and VAT (if applicable).* KJ CONTROLS LTD IS NOT AN AUTHORIZED DISTRIBUTOR FOR FLYGT / XYLEM FLYGT (40A1 - Upstairs Warehouse)

Variants (1)
  • Default Title — 512.00 USD — In stock

AI Readiness

Good foundation, but some important product data is still missing.

81%