Battery Fire Protection Device – Automatic Aerosol Fire Suppression

Battery Fire Protection Device – Automatic Aerosol Fire Suppression

Brand: LiFePO4 OZ
SKU: DC-QRJ001
59.95 AUD In stock Buy at Merchant

``` LiFePO4 Oz Battery Safety Technology Lithium Battery Fire Suppression Device A compact 5g hot-gas aerosol Fire Suppression Device designed for lithium battery boxes, PV inverter enclosures, electrical cabinets and other small, relatively enclosed spaces. 🔥 Automatic thermal activation ⚡ 5g aerosol agent 📦 Up to 0.05m³ protection ⏱️ ≤5-second release delay 🛡️ 10-year validity period Overview The Fire Suppression Device is a compact aerosol unit intended for installation inside small, relatively enclosed battery and electrical compartments. It contains 5g of S-type hot-gas aerosol agent and activates thermally at approximately 160°C to 180°C. Once activated, the unit releases the aerosol within five seconds to help suppress combustion. Its compact size makes it suitable for lithium battery boxes, energy storage equipment, PV inverter enclosures, electrical cabinets, communications equipment and similar confined spaces. Important Information This is a single-use Fire Suppression Device. Once the device has activated, it must be replaced. The unit should also be replaced when its stated 10-year validity period expires. Keep a minimum of 100mm clear in front of the discharge outlet. Do not block the outlet with wiring, equipment or other obstructions. 🌡️ Thermal Activation Activates at approximately 160°C to 180°C. 💨 Rapid Aerosol Release Release lag time of five seconds or less. 📦 Compact Protection Designed for enclosed volumes up to 0.05m³. 🛡️ 10-Year Validity Long-term installed protection before scheduled replacement. How the Fire Suppression Device Works Thermal activation The thermal lead activates when exposed to temperatures of approximately 160°C to 180°C. Aerosol generation Once activated, the device produces an S-type hot-gas aerosol that fills the protected enclosure. Cooling effect Fine aerosol particles absorb part of the heat released by the fire, helping to reduce flame temperature. Gas-phase inhibition Aerosol components react with active combustion particles, reducing the free radicals required to sustain the flame. Solid-phase inhibition Solid particles help absorb and neutralise combustion intermediates, further interrupting the fire reaction. Suitable Applications Lithium-ion and LiFePO4 battery boxes Battery compartments and battery cabinets Energy storage equipment PV and hybrid inverter enclosures Electrical control cabinets Power distribution cabinets Communication equipment Generator and engine compartments Cable compartments, wells and trenches Other relatively enclosed electrical spaces Technical Specifications Product Type Fire Suppression Device Model QRR0.005G/S Extinguishing Agent S-Type Hot-Gas Aerosol Aerosol Agent Quantity 5g ±1% Standard Activation Method Thermal activation Optional Activation Electric activation or combined thermal and electric activation Activation Temperature 160°C to 180°C Release Lag Time ≤5 seconds Protected Volume Up to 0.05m³ Ambient Operating Temperature -50°C to +90°C Dimensions 80 × 40 × 10mm Device Weight Approx. 30g ±10g Thermal Lead Length Approx. 200mm Mounting M3 screw fixing points on both sides Discharge Direction Single-end discharge Nozzle Temperature ≤200°C measured 5mm from the nozzle Validity Period 10 Years Applicable Fire Classes Class A, B, C and E fires in relatively enclosed spaces Compact Protection for Confined Electrical Spaces The QRR0.005G/S provides an automatic, compact and pipe-free fire suppression solution for lithium battery, inverter and electrical applications where space is limited. Its thermal activation, rapid aerosol release and small form factor make it suitable as an additional protection device inside compatible enclosed equipment. Installation and Safety Notes Keep at least 100mm clear in front of the discharge outlet. Do not obstruct the outlet with wiring, equipment or debris. Use the M3 mounting points to secure the device. Do not dismantle the device. Replace the unit after activation. Replace the unit when the 10-year validity period expires. After discharge, allow the housing to cool before touching it. Installation should be completed by a suitably qualified person. The device is intended for relatively enclosed spaces. Frequently Asked Questions Is the Fire Suppression Device reusable? No. The device is single-use and must be replaced after activation. Does the Fire Suppression Device need external power? The standard version is thermally activated and does not require an external power supply. Electric activation may be available as an optional configuration. What volume can it protect? The device is intended for relatively enclosed spaces with a volume of up to 0.05m³. What temperature activates the device? The thermal activation temperature is approximately 160°C to 180°C. How long is the device valid? The stated validity period is 10 years. It must also be replaced immediately after activation. Can it be installed inside a lithium battery box? Yes. It is designed for small, relatively enclosed spaces such as lithium battery boxes, battery compartments and electrical enclosures, subject to correct system design and installation. ```

Variants (1)
  • Default Title — 59.95 AUD — In stock

How AI sees this product

The more complete this product's details, the more confidently AI assistants can understand and recommend it.

84%