Victron Energy Multiplus-II 12/4k/160-50 120v #PMP122405100
Victron Energy PMP122405100 Inverters The Victron Energy PMP122405100 MultiPlus-II 12/4k/160-50 is a 120V inverter/charger for 12V electrical systems. Its configuration combines a 4 kVA inverter rating, 160A charger rating, and 50A AC transfer rating. The Victron MultiPlus-II 12/4000/160-50 combines a 120V inverter, high-output battery charger, and automatic transfer switch for marine, mobile, backup, and off-grid power systems. It delivers 3.4 kW of continuous inverter power at 25°C, supports demanding loads with 6 kW peak output, and provides up to 160 A of battery charging. PowerControl helps prevent shore power or a generator from being overloaded, while PowerAssist supplements limited incoming AC power with energy from the battery. KEY FEATURES Multifunction inverter, battery charger, and transfer switch Designed for nominal 12V battery systems 120V AC output Fixed 60 Hz model 3.4 kW continuous output at 25°C 4.0 kW time-limited output for up to 1 hour from a cold start 4.5 kW time-limited output for up to 30 minutes from a cold start 6 kW peak output for 2 seconds Maximum 160 A battery charging current 50 A automatic transfer switch PowerControl limits charging demand to help prevent AC source overload PowerAssist supplements shore, generator, or grid power with battery power Main AC output transfers to inverter power in less than 20 milliseconds Auxiliary AC output disconnects loads when external AC power is unavailable Four-stage adaptive charging with BatterySafe and storage modes VE.Bus support for monitoring, system integration, and multi-unit operation Remote on/off capability Programmable relay Two general-purpose communication ports Optional external 100 A AC current sensor support Configurable through VictronConnect or VEConfigure with an MK3-USB interface Compatible with Victron GX equipment and the VRM Portal for remote monitoring TECHNICAL SPECIFICATIONS Manufacturer part number: PMP122405100 Model: MultiPlus-II 12/4k/160-50 120V Frequency version: 60 Hz only DC input voltage range: 9.5-17V Inverter output voltage: 120 VAC ±2% Output frequency: 60 Hz ±0.1% Continuous output at 25°C: 3.4 kW Continuous output at 40°C: 3.1 kW Continuous output at 65°C: 2.4 kW Time-limited output: 4.0 kW for 1 hour from a cold start Time-limited output: 4.5 kW for 30 minutes from a cold start Peak output: 6 kW for 2 seconds Maximum efficiency: 93% Zero-load consumption: 18 W Zero-load consumption in AES mode: 11 W Zero-load consumption in Search mode: 4 W AC input voltage range: 90-140 VAC AC input frequency range: 55-65 Hz Maximum AC input current: 50 A Transfer switch rating: 50 A Maximum battery charge current: 160 A at 25°C Absorption voltage: 14.4V Float voltage: 13.8V Storage voltage: 13.2V Auxiliary AC output rating: 32 A Starter-battery maintenance charge output: 4 A External AC current sensor capacity: 100 A optional Operating temperature range: -40°C to 65°C (-40°F to 150°F), fan-assisted cooling Maximum non-condensing humidity: 95% Enclosure material: Steel Color: Blue, RAL 5012 Protection category: IP21 Battery connections: 2 x 2 M8 bolts AC connection conductor size: 6 AWG Weight: 49 lb (22 kg) Dimensions: 24.8 x 10.9 x 6.5 in. (631 x 277 x 164 mm) Listing: UL 458 The manual specifically identifies PMP122405100 as the 60 Hz-only version of the MultiPlus-II 12/4k/160-50 120V. APPLICATIONS Recreational vehicle electrical systems Marine house-power systems Work vehicles and specialty mobile equipment Generator-supported battery systems Shore-power installations Off-grid homes and cabins Backup power systems Solar and alternative-energy installations Energy storage systems Systems supporting computers and other sensitive electronics IDEAL FOR Buyers needing a combined inverter, charger, and transfer switch 12V battery banks requiring high charging current Systems with limited shore-power or generator capacity Applications with short-duration high-starting-power loads Installations that require selected loads to shut down during battery operation Expandable systems requiring parallel, split-phase, or three-phase capability Owners who want optional remote monitoring and system configuration PROTECTION FEATURES Output short-circuit protection Inverter overload protection High battery-voltage protection Low battery-voltage protection High-temperature protection Protection against 120 VAC being present on the inverter output Excessive input-voltage-ripple protection Bulk-charge time protection Alarm and shutdown indications for overload, low battery, high temperature, and excessive DC ripple SYSTEM COMPATIBILITY Designed for nominal 12V battery banks Supports lead-acid charging with adaptive bulk, absorption, float, and storage stages Compatible with Victron Lithium Battery Smart systems when used with a VE.Bus BMS V2 or Lynx Smart BMS Other lithium batteries require verified battery and BMS compatibility and appropriate charger configuration Compatible with solar charge controllers and grid-tie inverters in supported system designs Up to six identical units may be connected in parallel Two identical units may be configured for 120/240V split-phase output Three identical units may be configured for three-phase output Compatible monitoring and control options include Cerbo GX, Ekrano GX, Digital Multi Control, VE.Bus Smart Dongle, MK3-USB, VictronConnect, VEConfigure, and VRM Optional 100 A external current sensor can support grid-parallel PowerControl and PowerAssist applications CHECK BEFORE ORDERING Confirm that the 60 Hz-only PMP122405100 version is required. The similar PMP122405110 version supports 50/60 Hz operation. Confirm the system uses a nominal 12V battery bank. Confirm the required AC output is 120V at 60 Hz. Verify that 3.4 kW continuous output is sufficient for the combined running loads. Check motor, compressor, pump, and air-conditioning startup requirements against the 6 kW peak rating. The manual recommends a 400-1200 Ah battery bank for this model. Recommended DC fuse rating is 600 A. Recommended battery cabling is two 2/0 AWG conductors per positive and negative connection for runs up to 5 m. Recommended battery cabling is two 4/0 AWG conductors per positive and negative connection for runs from 5-10 m. AC input and main-output circuits are rated for 50 A and require appropriately sized overcurrent protection. The auxiliary output is limited to 32 A and turns off during inverter-only operation. Install in a dry, well-ventilated location with adequate cooling clearance. Parallel and multi-phase systems require identical units, equal-length DC cables, VE.Bus cabling, and system configuration. An MK3-USB interface and RJ45 UTP cable are required for direct computer configuration. Confirm battery chemistry, charging voltages, BMS requirements, and temperature-sensor requirements before installation. Normalized SKU: PMP122405100
Variants (1)
- Default Title — 1135.90 USD — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.