BarriAire™ Gold Elite Pro Particulate Hood Comprehensive Coverage
With Nomex® Nano Flex Sure‑Fit™ Panel and Face Opening Now Certified to the NEW NFPA 1970 Standard! Elite Pro hoods are specifically designed to improve comfort and provide greater freedom of movement while significantly reducing tugging or pulling away from the SCBA facepiece. Tapered back, notched shoulder drape and patterned bib perfectly interface with turnout collars and SCBA strapping. Designed to comfortably integrate with SCBA facepiece head harness and maintain proper seal with mask. Particulate coverage throughout entire head including Sure‑Fit™ panel at crown and entire bib. Fabric Description: Quilted composite with PFAS-free durable water resistant finish on the exterior layer and a dual-technology antimicrobial and anti-odor finish on the inside layer with Nomex® Nano Flex between layers for excellent stretch, recovery and odor control. Highest air permeability of particulate fire hoods on the market at 23 cfm, approximately 3-6 times greater than PTFE laminated hoods. Averages 97.4% particulate efficiency for particulates between 0.1 and 1.0 microns. PGI quilted BarriAire composite fabrics recently achieved Viral Filtration Efficiency (VFE) Rating of 96.8% and Bacterial Filtration Efficiency (BFE) Rating of 97.9% (as conducted by Nelson Labs, U.S.A.). NFPA 70E Hazard Risk Category 4. Test Results Fabric Performance Values Requirements NFPA 1970 2025 Edition PGI Test Results Particulate Efficiency Quilted Composite Lowest Average as Received ≥ 90% 97.4% Lowest Average after 10 Launderings ≥ 90% 97.3% Seam at Crown and Panels Lowest Average as Received ≥ 90% 95.5% Lowest Average after 10 Launderings ≥ 90% 98.4% Seam at Drape Attachment Lowest Average as Received ≥ 90% 95.7% Lowest Average after 10 Launderings ≥ 90% 97.5% Viral & Bacterial Filtration Efficiency Viral Filtration Efficiency (VFE) N/A 96.8% Bacterial Filtration Efficiency (BFE) N/A 97.9% Air Permeability (As Received) N/A 23 cfm Thermal Protective Performance (TPP) 20.0 (min) 25.7 Total Heat Loss (THL) ≥ 325 W/m2 379.5 W/m2 Hood Material Burst Strength ≥ 225 N 1352 N Flame Resistance Test – Quilted Composite After Flame (Wales x Courses) As Received ≤ 2.0 sec 0.3 sec x 0.7 sec After 5 Washings ≤ 2.0 sec 1.3 sec x 1.0 sec Char Length (Wales x Courses) As Received ≤ 100 mm 27 mm x 4 mm After 5 Washings ≤ 100 mm 7 mm x 3 mm Cleaning Shrinkage Resistance Test Hood Measurement After 5 Washings ≥ -5% 0.7% Face Opening Measurement After 5 Washings Meets Requirement YES Heat & Thermal Shrinkage Resistance Test Hood Measurement As Received ≥ -10% -1.8% After 5 Washings ≥ -10% -0.3% Face Opening Measurement As Received Meets Requirement YES After 5 Washings Meets Requirement YES Limited Oxygen Index (LOI) Not Required 40 Seam Breaking Strength Test Crown and Panels ≥ 181 N 1389 N Drape Attachment ≥ 181 N 1139 N Melt or Drip When Exposed to Flame No Melting or Dripping NONE Arc Thermal Performance Value (ATPV) 46 cal/cm2 NFPA 70E Hazard Risk Category (HRC) HRC 4
Variants (1)
- Default Title — 0.00 CAD — In stock
AI Readiness
Good foundation, but some important product data is still missing.