IS200JPDPG1A General Electric Power Distribution Board | New & Original Stock
Configured for power distribution and circuit protection in turbine control cabinets, the General Electric IS200JPDPG1A (IS200JPDPG1A Local Power Distribution Board) provides direct physical/electrical execution. Suffix Breakdown & Model Matrix The IS200JPDPG1A identifier signifies the base configuration of the local DC power distribution panel. The "G1A" suffix denotes the specific board revision and component layout, optimized for high-current 125 VDC management. This module serves as a static power distribution hub, providing fused pathing for down-stream control components without variable software-defined logic. Hardware Specifications Parameter Specification Model IS200JPDPG1A Brand General Electric Origin USA Weight 0.95 kg Dimensions 220 mm x 140 mm x 35 mm Operating Temp Not specified (Standard industrial) Power Consumption Not applicable (Passive distribution) Main Input 1 Channel, 125 VDC ± 20% Fused Outputs 8 Channels, 10 A per channel Surge Suppression MOV, 150 VDC clamping Backplane Bus Communication and Firmware Compatibility The IS200JPDPG1A is a passive electrical distribution component and does not participate in active backplane bus communication or require firmware. It ensures the integrity of the control power supply by utilizing high-capacity bus bars and fast-blow fuse protection. Signal integrity for connected I/O is maintained through low-impedance power paths, ensuring a voltage drop of < 0.8 VDC at full load, which supports the deterministic operation of downstream I/O packs. Frequently Asked Questions Q: What type of fuses are required for replacement on this board? A: The board utilizes 10 x 38 mm fast-blow fuses with a 10 A rating per channel. Always ensure the circuit is de-energized before replacing any fuse to avoid arcing. Q: How does the board protect against voltage transients? A: The board incorporates Metal Oxide Varistors (MOV) with a 150 VDC clamping voltage, providing surge suppression for the 125 VDC input supply to protect downstream control hardware. Field Installation Guidelines Ensure the main 125 VDC source is isolated and locked out before connecting input wiring to the terminal blocks. Secure the board to the cabinet backplane using all available mounting holes to prevent mechanical vibration and ensure thermal dissipation. Terminate input and output wiring to the specified terminal blocks, ensuring proper torque to prevent high-resistance connections at the 10 A rated load. Verify that the fuse integrity is maintained by checking for continuity if the downstream load fails to power up. Keep input power leads separated from sensitive communication and analog signal cables to minimize inductive coupling and electromagnetic interference.
Variants (1)
- Default Title — 220.00 USD — In stock
AI Readiness
Good foundation, but some important product data is still missing.