DrainGuard Condensate Drain Cable Entry Kit, 1 to 1-1/2 in

DrainGuard Condensate Drain Cable Entry Kit, 1 to 1-1/2 in

Brand: YeloDeer
SKU: Y-DGK-EK
37.99 USD In stock Buy at Merchant

Overview Y-Fitting Cable Entry for Larger Condensate Drain Lines YeloDeer DrainGuard DGK-EK provides the fittings and cable-entry seal needed to install the YeloDeer IPHC-DMi self-regulating heating cable inside a nominal 1 in, 1-1/4 in, or 1-1/2 in non-pressurized condensate drain. It is suited to compatible HVAC, condensing furnace, boiler, and water-heating system drain lines. The heating cable is sold separately. Key Buying Information Best For Condensate drain lines that need a dedicated cut-in heating cable entry. Pipe Size Nominal 1 in, 1-1/4 in, or 1-1/2 in PVC or ABS drain pipe. Matching pipe size alone does not ensure heating cable compatibility. Included PVC Y-fitting, pipe nipples, size reducers, rubber gasket, sealing grommet, and lock nut. Sold Separately YeloDeer IPHC-DMi condensate drain heating cable, pipe-joining materials, and any additional repair coupling required by the installation. Choose the Right Condensate Drain Setup 1 to 1-1/2 in Pipe: Pair with IPHC-DMi Only Use this DGK-EK fitting kit only with the YeloDeer IPHC-DMi condensate drain heating cable, purchased separately. The included rubber sealing grommet is sized for this cable. The thicker IPHC-DMa sewer and wastewater heating cable does not fit through the included sealing grommet. Select the cable length and output for the actual drain route. 1/2 or 3/4 in Pipe: Complete Kit Choose the DrainGuard condensate drain heating cable kit. It includes a heating cable and fittings sized for those smaller drain lines. Confirm before ordering: DGK-EK is for non-pressurized drains only. Check the nominal pipe size, material, drain condition, internal cable route, and working space. The fitting does not make a drain pressure-rated. Applications Condensate Drain Applications DGK-EK is intended for compatible condensate drain lines exposed to freezing where a separate Y-fitting entry is needed to route an in-drain heating cable toward the vulnerable section. HVAC Condensate Heat PumpsAir HandlersCold-Space Drain Runs Condensing Furnace Drains Furnace CondensateExterior Wall ExitsUnheated Areas Boiler & Water-Heating Drains Boiler CondensateWater-Heater CondensateUtility Areas Pipe Compatibility Use only with supported nominal 1 in, 1-1/4 in, or 1-1/2 in non-pressurized PVC or ABS drain pipe. The supplied fittings are PVC. Connecting them to ABS requires an appropriate PVC-to-ABS transition method where required by local code and the joining-material manufacturer's instructions. Do not use this kit in pressurized plumbing, potable-water supply, fuel or gas piping, chemical transfer lines, unsupported pipe sizes, or a frozen, blocked, collapsed, or damaged drain. Specifications Fitting Kit Specifications Model DGK-EK Product Type Y-fitting cable-entry and sealing kit; heating cable not included Primary Application Non-pressurized condensate drain lines Supported Nominal Pipe Sizes 1 in, 1-1/4 in, and 1-1/2 in Compatible Drain Materials PVC or ABS, using the correct joining method Supplied Fitting Material PVC Compatible Heating Cable YeloDeer IPHC-DMi only, sold separately. The included sealing grommet does not fit the thicker IPHC-DMa cable. What Is Included One 1-1/2 in Y-fittingThree 1-1/2 in pipe nipples Two 1-1/2-to-1 in reducersTwo 1-1/2-to-1-1/4 in reducers One 1-1/2-to-3/4 in cable-entry reducerOne rubber gasket One sealing grommetOne lock nut The 1-1/2 in pipe configuration uses the Y-fitting without main-run size reducers. The 1 in and 1-1/4 in configurations use their respective reducer pairs and pipe nipples. Installation Before Cutting the Condensate Drain Check the Line Thaw or clear the drain first. Confirm it is intact, non-pressurized, and draining normally. Check the Fit Dry-fit the correct reducer configuration and confirm working clearance and full socket insertion depth. Check the Cable Route Confirm the cable can travel toward the downstream outlet without a blockage or sharp restrictive bend. Check Joining Materials Use materials appropriate for the actual pipe and fittings, including a PVC-to-ABS transition method when required. Basic Installation Sequence Keep the heating cable disconnected from power. Measure and cut the selected drain section conservatively; deburr and clean both pipe ends. Position the Y-fitting so the cable-entry branch points upward or upward at an angle toward the downstream drain outlet. Join the Y-fitting, pipe nipples, and correct reducers. Allow bonded connections to cure according to the joining-material instructions. Feed the compatible heating cable through the angled branch without forcing, kinking, crushing, or scraping it. Seat the rubber gasket and sealing grommet, then tighten the lock nut evenly. Do not modify the sealing parts or overtighten. Run water through the condensate drain and check all joints and the cable entry for leaks before connecting power. Follow the heating cable manual for electrical requirements. Pipe Cut Reference 1-1/2 in Condensate Drain Recommended section to remove: 3.5 in / 9 cm 1 or 1-1/4 in Condensate Drain Recommended section to remove: 11.8 in / 30 cm Verify the actual assembled fit before the final cut. Rigidly fixed pipe ends may require an additional approved repair or slip coupling, which is not included. FAQ Does DGK-EK include a heating cable? No. DGK-EK contains the condensate drain entry fittings and sealing components only. Purchase the YeloDeer IPHC-DMi condensate drain heating cable separately. The included sealing grommet is sized for IPHC-DMi and does not fit the thicker IPHC-DMa cable. Which condensate drain sizes does it fit? It supports nominal 1 in, 1-1/4 in, and 1-1/2 in drain pipes using the included fitting configurations. Confirm the actual pipe dimensions before installation. Is this the right kit for a 1/2 or 3/4 in condensate drain? No. DGK-EK is sized for 1 to 1-1/2 in pipes. The separate DrainGuard heating cable kit includes the cable and fittings for compatible 1/2 and 3/4 in condensate drains. Can the PVC fittings connect to an ABS condensate drain? Yes, when the drain is otherwise compatible and the connection uses an appropriate PVC-to-ABS transition method where required by local code and the joining-material instructions. Can I install this in a pressurized water line? No. DGK-EK is designed for non-pressurized drains. Its cable-entry seal is not a pressure-rated connection for water-supply plumbing. What if the existing pipe ends cannot move apart? An approved repair or slip coupling, or another suitable plumbing method, may be needed to seat the fitting assembly fully. Additional repair fittings are not included. Guides Read the DGK-EK installation manual before cutting the condensate drain. Use the separately purchased heating cable's manual for cable routing and electrical requirements. For help choosing between external and in-drain heating on a condensate line, read When External Heat Tape Is Not Enough for Condensate Drain Lines.

Variants (1)
  • Default Title — 37.99 USD — In stock

How AI sees this product

The more complete this product's details, the more confidently AI assistants can understand and recommend it.

89%