Abatement Technologies RPM-RT2 Dual Room Differential Pressure Monitor
The RPM-RT2 is Abatement Technologies' dual-room wall-mounted differential pressure monitor. It simultaneously monitors and records the pressure relationships between three locations — two monitored rooms and a reference area — providing 24/7 oversight of negative and positive pressure conditions in patient isolation rooms, protective environments, cleanrooms, hospital construction zones, and central sterilization/sterile processing departments. The RPM-RT2 shares the same touchscreen interface, alarm system, logging, and network capabilities as the RPM-RT1, with the addition of a second pressure sensor input (ROOM B) and support for two RPM-RTSENSOR temperature/humidity sensors. If you only need to monitor one room, see the RPM-RT1. RPM-RT1 vs. RPM-RT2 — Which Monitor Do You Need? RPM-RT1 RPM-RT2 Pressure Inputs 1 (ROOM A) 2 (ROOM A + ROOM B) Rooms Monitored 1 2 simultaneously Temp/RH Sensors Up to 2 Up to 2 Kit P/N RPM-RT1K RPM-RT2K Features The RPM-RT2 monitors the pressure differential between each room and the adjacent reference area across a range of -0.10 in. water gauge (-25 Pa) to +0.10 in. water gauge (+25 Pa). Alarm thresholds are configurable from -0.04 to +0.04 in. water gauge (-10 to +10 Pa) at 0.001 in. WC (0.025 Pa) resolution. The color-coded touchscreen background — green, yellow, or red — provides instant visual status for both rooms from across the room. Audible alarms include delay and timed shutoff settings. Password protection is included and can be disabled. Data is logged to internal non-volatile memory (up to 12,000 events) and can be exported in CSV format via USB flash drive or accessed via BACnet or N2 network protocols for building management system integration. Calibrations are traceable to NIST standards. Optional RPM-RTSENSOR temperature and relative humidity sensors can be added to either or both rooms. When sensors are connected, temperature and RH data is logged alongside pressure data and can trigger independent alarms when set limits are exceeded. Sensors and cables are not included with the base RPM-RT2 — see the kit configuration (RPM-RT2K) or order sensors and cables separately. Technical Specifications Model RPM-RT2 Pressure Inputs 2 (ROOM A and ROOM B) Pressure Range -0.10 in. WC (-25 Pa) to +0.10 in. WC (+25 Pa) Alarm Range -0.04 in. WC (-10 Pa) to +0.04 in. WC (+10 Pa) Alarm Resolution 0.001 in. WC (0.025 Pa) Display Color-coded touchscreen | green / yellow / red alarm status Alarms Visual and audible | audio delay and timed shutoff Data Logging Up to 12,000 events in non-volatile internal memory Data Export USB flash drive (CSV format) Network BACnet and N2 compatible Temp/RH Sensors Supports up to 2 × RPM-RTSENSOR (sold separately) Calibration NIST-traceable Mounting Wall-mounted | wall cutout template included Password Protection Yes — can be disabled Best Suited For Patient isolation rooms | protective environments | cleanrooms | hospital construction | sterile processing departments Kit Configuration (RPM-RT2K) The RPM-RT2K kit includes: 1 × RPM-RT2 pressure monitor | 2 × 25 ft clear tubing (HCPDPMTUBE) | 2 × RPM-RTSENSOR temperature/RH sensors | 2 × 25 ft Ethernet cables (RPM-CABLE-025). Optional Accessories (Sold Separately) RPM-RTSENSOR Remote temperature and relative humidity sensor RPM-CABLE-025 25 ft Ethernet cable — required to connect each RPM-RTSENSOR Use only Abatement Technologies OEM sensors and cables with the RPM-RT series monitors. Abatement Advantage Pricing The RPM-RT2 is eligible for Abatement Advantage volume discount pricing. Contact us for pricing on multi-unit orders.
Variants (1)
- Default Title — 1617.49 USD — In stock
AI Readiness
Good foundation, but some important product data is still missing.