UniFi Enterprise Access Hub
Overview Dimensions379 x 355 x 105 mm (15 x 14 x 4.1″)Supported Doors8Maximum User Count10,000Input Terminals(8) Door exit request(8) Door position(1) EmergencyPower MethodUniversal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32VNDAA Compliant✓UL 294 LevelDestructive attack: Level ILine security: Level IEndurance: Level IStandby power: Level I Mechanical WeightDevice: 9.1 kg (20 lb)Mount: 624 g (1.4 lb)Enclosure MaterialSGCC steel housing with polycarbonate coverMount MaterialSGCC steelMountingWall Hardware Digital Input(8) Inputs for request-to-exit devices(8) Inputs for door position sensors(1) EmergencyDry Output Relay(8) Lock terminals (12V or Dry)(4) AUX terminals for advanced setup (Chime/Siren/Door opener)Powered Output RelayLock: 12V DC, 1A/ DryAux: Dry onlyIndoor and Outdoor UseIndoor onlyAmbient Operating Temperature0 to 40° C (32 to 104° F)Ambient Operating Humidity5 to 95% noncondensingNetworking Interface(10) 10/100/1000 Base-TPoE Interface(8) PoE+ outputs, 50V DC, 30W per port(Max 190W aggregated)Power SupplyAC/DC, internalMax. Power Consumption240WMax. PoE Wattage per Port30WLEDsW/B Learn MoreButtons(1) Factory resetRecommend Max. Cable Length UA-Lock-Electric(400mA) 24 AWG length: 25 m (82 ft)22 AWG length: 42 m (138 ft)20 AWG length: 66 m (217 ft)18 UACC-Cable-DoorLockRelay length: 100 m (328 ft) UA-Lock-Magnetic-540kg (500mA) 24 AWG length: 20 m (66 ft)22 AWG length: 32 m (105 ft)20 AWG length: 51 m (167 ft)18 UACC-Cable-DoorLockRelay length: 80 m (262 ft) UA-Lock-Magnetic-270kg (800mA) 24 AWG length: 12 m (39 ft)22 AWG length: 20 m (66 ft)20 AWG length: 30 m (98 ft)18 UACC-Cable-DoorLockRelay length: 46 m (151 ft) Other locks(1A) 24 AWG length: 9 m (30 ft)22 AWG length: 15 m (49 ft)20 AWG length: 24 m (79 ft)18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)PoE Cabling RequirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.CAN/ULC-60839-11-1 GradeGrade assignment: ICertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1Document number, and issue date and/or revision levelEAH-8, Ver 01 Software Management ApplicationAccessSoftware InformationThe software version can be checked at https://unifi.ui.com
Specifications
- แบรนด์
- Ubiquiti
AI Readiness
Good foundation, but some important product data is still missing.