GE FANUC A03B-0819-C052 Analog Output Module

GE FANUC A03B-0819-C052 Analog Output Module

Brand: GE FANUC
SKU: A03B-0819-C052
220.00 USD In stock Buy at Merchant

The GE FANUC A03B-0819-C052, also cataloged as the A03B-0819-C052 Analog Output Module, operates as a dedicated hardware component for sequential relay control and signal conversion within GE FANUC Series I/O architectures. Hardware Specifications Parameter Specification Model A03B-0819-C052 Brand GE FANUC Origin Japan Weight 0.81 lbs (0.37 kg) Dimensions Standard A03B module form factor Operating Temp 0 to 45 deg C Power Consumption Backplane powered (Standard I/O bus load) Number of Channels 2 channels Resolution 12-bits Analog Output (Voltage) -10 VDC to +10 VDC Analog Output (Current) 0 mADC to +20 mADC Voltage Resolution 5 mV Current Resolution 20 uA Terminal Block Included Deterministic Backplane & Bus Synchronization The module interfaces directly with the GE FANUC rack assembly through the system backplane bus communication velocity architecture. Digital commands received over the backplane bus undergo high-speed 12-bit digital-to-analog conversion, maintaining strict deterministic update intervals to prevent signal delay in sequential relay control loops. Channel circuitry features embedded firmware flash compatibility to maintain uninterrupted execution during high-density I/O scan cycles. Frequently Asked Questions Q: What are the hot-swap limitations when replacing the A03B-0819-C052 module on the rack? A: Module replacement requires total backplane power isolation prior to removal. Hot-swapping while the base rack is energized risks backplane bus disruption and hardware damage. Q: How does the module handle signal scaling for voltage and current outputs? A: The integrated 12-bit D/A converter maps digital counts to a 5 mV voltage step size (-10 VDC to +10 VDC range) or a 20 uA current step size (0 mADC to +20 mADC range) without hardware jumper reconfiguration. Field Installation Guidelines Mounting and Insertion: Align the module card edges with the designated slot guide rails on the backplane rack. Insert firmly until the locking mechanisms fully engage. Grounding Requirements: Ensure the DIN-rail or rack chassis is connected to a low-impedance functional earth (FE) ground point using a minimum 14 AWG copper conductor. Wiring Practice: Route analog signal cables in separate conduits isolated from high-voltage AC lines. Use shielded twisted-pair cabling for all output channels. Ground the cable shield at the controller side only to prevent ground loop currents. Terminal Block Wiring: Connect field wiring to the included terminal block. Torque terminal screws to 0.5 Nm (4.4 in-lbs) to maintain stable electrical contact.

Variants (1)
  • Default Title — 220.00 USD — In stock

How AI sees this product

The more complete this product's details, the more confidently AI assistants can understand and recommend it.

89%