Megger PAT150R Landlords PAT Testing Kit
The Megger PAT150R Landlords PAT Testing Kit is a practical solution for landlords and property managers carrying out routine portable appliance testing across rental properties. The PAT150R performs essential tests including earth bond continuity, insulation resistance, polarity and substitute leakage, with automatic test sequences for Class I and Class II appliances, IEC equipment and extension leads helping to simplify inspections. Portable RCD testing and earth/touch leakage current measurements provide additional testing options where required, while the backlit display and clear PASS/FAIL indications make results easy to interpret. Its rechargeable battery and integrated charger make it convenient to move between properties without relying on a mains supply. The kit includes accessories to support testing, record keeping and safe maintenance work. PAT Testing Kit Comparison Guide Small Business PAT Testing Kit Landlords PAT Testing Kit Maintenance PAT Testing Kit Industrial PAT Testing Kit Test Meter Kit Bag ✔ ✔ ✔ x 2 PAT Register Book ✔ ✔ ✔ ✔ PAT Certificate Pad ✔ ✔ ✔ ✔ Test Meter PRO TMP989 230V 13A Socket Tester ✔ ✔ IEC Cloverleaf Adaptor ✔ IEC Adaptor Kit ✔ ✔ ✔ 500 Pass labels x 2 x 2 x 2 x 2 250 Pass Wrap labels ✔ x2 x 2 x 2 200 Fail labels ✔ ✔ ✔ ✔ 250 Tuff Tag Cable Wrap Labels ✔ ✔ 16A 110V Appliance Adaptor and Extension Lead Adaptor ✔ ✔ PL13 230V 13A Plug Lockout & Padlock ✔ ✔ 16A 230V Appliance Adaptor and Extension Lead Adaptor ✔ ✔ 32A 110V Appliance Adaptor and IEC Extension Lead Adaptor ✔ 32A 230V Appliance Adaptor and Extension Lead Adaptor ✔ 16A & 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors ✔ Key Features Purpose-built PAT testing kit for landlords and property managers Automatic Class I, Class II, IEC lead and extension lead test sequences Performs essential PAT tests plus RCD and leakage current measurements Rechargeable PAT tester with integrated battery charger Includes plug lockout and padlock for safer isolation of faulty appliances Supplied with documentation, certificates and appliance labels for complete record keeping IEC Cloverleaf Adaptor supports testing of compatible household and office equipment Portable kit bag for convenient transport between properties Clear PASS/FAIL indications simplify appliance assessment Specifications Environmental Conditions Operating ambient: 20°C Humidity: Nominal humidity Continuity Test Test voltage: Compliance Voltage: +4V dc, –0 % /+10 % (open circuit) Test current: Bi-directional +200mA, -0% + 50mA (into 2Ω load) Continuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω) Resistance resolution: 10 mΩ Display range: 0.01 to 19.99Ω Continuity test nulling: up to 9.99 Ω Test time: User selectable from 2 sec to 20 sec or selected during test to 180sec Insulation Test Insulation test: 250V dc –0 % /+25 % open circuit, 500V dc –0 % /+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load Short circuit/charge current: < 2mA dc Insulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ) Resolution: 0.01 MΩ Display range: 0.10 MΩ to 99.99 MΩ Test duration: User selectable from 2 sec to 20 sec or selected during test to 180sec Substitute Leakage Test Leakage current: Accuracy ± 5% ± 3 digits Test frequency: Nominal mains frequency 50Hz Test voltage: < 50V ac Resolution: 0.01mA Display range: 0.10 to 19.99mA Test duration: User selectable from 2 sec to 5 seconds Reading corrected to 230V ac. Touch Current Test Test voltage: Nominal mains 230 V ac Test frequency: Nominal mains 50 Hz Test accuracy: ± 5% ± 3 digits Resolution: 0.01 mA Display range: 0.10 to 3.99 mA Test duration: User selectable from 2 sec to 5 sec SELV Device Test Test voltage: 0 to 300 V ac Measurement accuracy: ± 3% ± 3 digits Resolution: 0.1 V ac Display range: 0.1 to 300 V ac Extension Lead Test Test includes Insulation and Bond tests. Test voltage: 5V Polarity: Lead OK, Live/neutral shorted, Live/neutral reversed, Live/neutral open circuit Portable RCD Test Test voltage: Nominal mains 230 V Test frequency: 50Hz Test current accuracy: +2% to +8% (1 x I, 5 x I) Trip time accuracy: ±1% ± 1ms Trip time resolution: 0.01ms Display range: 0 to 200ms (1 x I), 0 to 40ms (5 x I) Mains Supply Test Frequency measurement range: 50 Hz Test voltage: 40 to 300V ac Accuracy: ± 3% ± 3 digits Resolution: 0.1Vac Display range: 40 to 300V ac Circuit Test Carried out automatically, not available to user. Test voltage: 5V Test frequency: Nominal Mains 50 Hz Test current: < 100mA short circuit Safety Instrument designed to IEC 61010-1: 2012 Test leads designed to IEC 61010-031: 2005 300 volts to Earth Category II Mains fuse protection to 250 volts rms ac EMC Design to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005. Environmental Operating temperature range: 0°C to +40°C Storage temperature range: -20°C to +60°C Humidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C Maximum altitude: 2,000m to full safety spec. IP rating: IP40 (with front cover closed) General Battery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6) Weight (PAT150 Only): 1300g Weight (Shipping): 2795g / 2975g for PAT150R Dimensions: 203 x 148 x 78mm Megger Part Number: 1003-064 / 1003-428 (rechargable model) Supplied Accessories Megger PAT150R Tester Test-Meter Kit Bag PAT Register Book PAT Certificate Pad Test Meter PRO TMP989 230V 13A Socket Tester IEC Cloverleaf Adaptor 2 x 500 Pass labels 2x 250 Pass Wrap labels 200 Fail labels PL13 230V 13A Plug Lockout & Padlock Videos
Variants (1)
- Default Title — 669.00 GBP — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.