Solis 100kW Three Phase Hybrid Solar Inverter High Voltage S6-EH3P100K10-NV-YD-H
Solis 100kW Three Phase Hybrid Solar Inverter High Voltage S6-EH3P100K10-NV-YD-H The Solis S6-EH3P100K10-NV-YD-H is a 100kW three phase high voltage hybrid inverter built for commercial and industrial energy storage. One unit manages up to 200kW of solar, two high voltage battery banks, the grid supply and a standby generator, which makes it a practical centre for a site that wants to cut peak demand and ride through outages. It sits in the middle of the Solis Solarator 80 to 125K series. Typical sites include warehouses, manufacturing units, agricultural buildings and commercial premises with strong daytime demand. The 10 MPPT design, 200A of combined battery charge current and a dedicated generator input give installers room to size the system around how the site really uses power. High Solar Input for Large Arrays The 100kW model supports a recommended PV array of up to 200kW, twice its rated output, with a maximum input voltage of 1000V, a rated voltage of 600V and a wide MPPT range from 150V to 950V. Ten independent MPPT trackers take 20 strings in total, and each input handles up to 42A (21A per string), so it works with high power PV modules. Two Ports for High Voltage Batteries The inverter works with high voltage lithium batteries from 300V to 950V. Two independent battery ports, each with its own BMS connection, charge and discharge at up to 100A each, giving up to 200A of combined charge current for fast charging. Solis rates the range for battery modules from 100Ah to 314Ah, and the twin ports make it straightforward to split storage or add capacity later. Battery communication is via CAN. Backup Power, Generator and Weak Grid Support On-grid to off-grid switching takes less than 10ms for a single inverter, so critical loads carry on through a grid failure. In backup mode the 100kW model delivers 160% of rated power for 10 seconds and 200% for 200 milliseconds, which helps start motors, compressors and pumps. Battery reserve management and intelligent load prioritisation stretch the supply time for the loads that matter most. A dedicated generator input rated at 100kW, flexible control for weak grid and genset hybrid systems, and a utility bypass that feeds backup loads directly from the grid all help keep a site running when the supply is unreliable. Commercial Energy Management Solar and storage work together for demand management and anti reverse flow (export limiting), and dynamic reactive power compensation helps improve the site power factor and reduce reactive power charges. AI integration and virtual power plant (VPP) readiness support dynamic tariff optimisation. Both DC and AC coupling are supported, and a three in one interface connects on-grid PV, wind power and diesel generators. Parallel Operation up to 1.25MW Multiple units can run in parallel for systems up to 1.25MW, with a Solis STS cabinet recommended above 6 inverters. In a parallel system of up to 6 inverters the switchover time is below 20ms. Each phase carries up to 33% of rated power, so plan for a balanced three phase load. Monitoring and Communication A 7 inch LCD display, Bluetooth and the Solis app handle local setup and commissioning. Wi-Fi, LAN and Bluetooth are standard and 4G is optional. The unit also provides two CAN-BMS ports, two CAN parallel ports, RS485 for the meter, RS485, DRM, five digital inputs and four digital outputs. This version is supplied with a CT or meter in the box. Built for Demanding Sites An IP66 enclosure, intelligent redundant fan cooling and Solis patented cooling design keep the inverter working from -25°C to +60°C, in 0 to 100% relative humidity and at altitudes up to 3000m. Applications Commercial and industrial solar PV with battery storage Farms, cold stores and agricultural buildings Factories, warehouses and workshops Peak demand reduction and export limiting Backup power for critical loads Sites with a weak grid or a standby generator Installation Notes The S6-EH3P100K10-NV-YD-H is a high voltage battery inverter. It must only be used with compatible high voltage lithium battery systems in the 300V to 950V range and is not suitable for 48V battery banks. Solis lists G99 among the planned grid connection standards for this range, so please confirm certification status with us before specifying it for a UK grid connection. Installation, commissioning and grid connection must be completed by a qualified installer, with correct DC fusing, AC protection, surge protection and earthing. The unit weighs 170kg and measures 1174 x 814 x 400mm, so plan handling and mounting accordingly.
Variants (1)
- Default Title — 10066.23 EUR — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.