NuAire LabGard NU-560-600 Biosafety Cabinet
NuAire LabGard NU-560-600 6' Class II Type B2 Total Exhaust Biosafety Cabinet – Used & Refurbished Refurbished NuAire NU-560-600 Type B2 Biosafety Cabinet for Sale The NuAire LabGard ES TE NU-560-600 is a 6-foot Class II Type B2 total exhaust biosafety cabinet designed to provide personnel, product, and environmental protection during biological research, pharmaceutical preparation, biotechnology applications, and laboratory procedures requiring externally exhausted containment. Unlike Class II Type A2 biosafety cabinets, the NU-560-600 uses a 100% total exhaust configuration, with no recirculation of air within the cabinet. Part of NuAire's LabGard ES Energy Saver series, the NU-560-600 combines a spacious stainless steel work chamber with an energy-efficient electronically commutated motor, advanced TouchLink electronic controls, continuous airflow monitoring, and redundant exhaust safety interlocks. The cabinet is designed for direct connection to a dedicated facility exhaust system capable of maintaining the required airflow and negative-pressure conditions. All air entering the cabinet is exhausted through HEPA filtration and discharged outside the building through the facility exhaust system. The NU-560-600 is particularly well suited to laboratories performing procedures involving biological materials in combination with limited quantities of volatile chemicals or radionuclides, when permitted by an appropriate risk assessment and facility safety requirements. With approximately 70.4 inches of interior working width, the cabinet provides substantial space for pharmaceutical research, biotechnology procedures, drug preparation, tissue culture, and other specialized applications requiring a Class II Type B2 containment environment. American Instrument Exchange offers the NuAire NU-560-600 as a professionally refurbished biosafety cabinet. The cabinet is inspected, cleaned, refurbished, and functionally tested before shipment, with new HEPA filters installed unless otherwise specified. A 90-day warranty is included from American Instrument Exchange. Key Features Class II Type B2 total exhaust biological safety cabinet NuAire LabGard ES Energy Saver TE series Model NU-560-600 6-foot nominal cabinet width 100% externally exhausted airflow with no internal recirculation Approximately 70.4-inch interior working width Type 304 stainless steel pressure-tight construction Energy-efficient DC electronically commutated motor TouchLink electronic control system Digital exhaust airflow monitoring Downflow velocity sensor Redundant exhaust failure protection Mechanical pressure switch and electronic exhaust monitoring HEPA-filtered supply and exhaust airflow HEPEX spring-loaded HEPA filter-sealing system ISO Class 5 clean-air performance Nominal 105 FPM inflow velocity Nominal 60 FPM downflow velocity 8-inch working sash opening Tempered-glass sliding sash LED work-area lighting One-piece dished stainless steel work tray Right-side electrical cord pass-through Integrated electrical receptacle USB and RS-232 data connections Direct connection to a dedicated facility exhaust system required Refurbished and tested by American Instrument Exchange 90-day warranty included Overview The NuAire NU-560-600 is engineered for laboratory procedures requiring the enhanced exhaust capabilities of a Class II Type B2 biosafety cabinet. During normal operation, room air enters through the front opening to provide personnel protection. Separately supplied HEPA-filtered downflow air moves vertically through the work chamber to provide product protection. Rather than recirculating air within the cabinet, the NU-560-600 directs all airflow through the exhaust filtration system and into a dedicated external exhaust connection. The cabinet's internal blower supplies the HEPA-filtered downflow air, while an external facility exhaust blower provides the suction required to remove the combined inflow and downflow air. The relationship between these two airflow systems is critical to containment performance. NuAire addresses this requirement through its TouchLink control system, digital exhaust flow grid, downflow sensor, and redundant exhaust failure interlocks. These systems help operators monitor cabinet performance and reduce the risk of unsafe operation if facility exhaust is lost. The NU-560-600 is therefore fundamentally different from a recirculating Type A2 biosafety cabinet and requires specialized installation, exhaust coordination, and certification. Why Choose the NuAire NU-560-600? The NuAire NU-560-600 is particularly attractive for laboratories that require both biological containment and complete external exhaust of cabinet airflow. Its Class II Type B2 design makes it suitable for certain specialized applications where recirculation of potentially contaminated air within the cabinet would be inappropriate. The large 6-foot work chamber provides ample room for laboratory equipment, reagent containers, sample racks, and complex preparation procedures. TouchLink controls continuously display important airflow parameters, helping operators recognize changing conditions and respond to alarms. The energy-efficient DC motor provides dependable downflow operation, while the redundant exhaust safety system helps protect against loss of facility exhaust. The stainless steel interior and removable work tray support routine cleaning, maintenance, and decontamination. For laboratories with appropriate facility exhaust infrastructure, the NU-560-600 offers a sophisticated containment solution combining total exhaust operation, intelligent monitoring, and substantial working space. Class II Type B2 Total Exhaust Technology The defining feature of the NuAire NU-560-600 is its 100% total exhaust airflow configuration. Unlike Class II Type A2 biosafety cabinets, which typically recirculate approximately 70% of their airflow, the NU-560-600 does not recirculate air within the cabinet. HEPA-filtered supply air enters the work chamber as vertical downflow. Room air simultaneously enters through the front opening, helping prevent potentially hazardous aerosols from escaping into the laboratory. Both airflow streams are drawn into the exhaust system and discharged through HEPA filtration to the facility's dedicated external exhaust system. This arrangement provides biological containment while preventing cabinet air from being recirculated internally. Because HEPA filtration removes particles but does not remove chemical vapors, the external exhaust system is essential for applications involving permitted quantities of volatile chemicals. The NU-560-600 should be selected based on a documented risk assessment, the substances being handled, and the facility's ventilation capabilities. Dedicated Facility Exhaust Requirements The NuAire NU-560-600 requires a properly engineered external exhaust system for operation. The manufacturer's published direct-connection exhaust requirement for the 6-foot model is approximately 1,275 CFM at 1.8 inches water gauge static pressure. The facility exhaust system must be capable of maintaining the required airflow under actual operating conditions, including ductwork resistance, exhaust filtration, building pressure, and other relevant factors. Unlike a Type A2 cabinet that may be able to discharge HEPA-filtered exhaust into the laboratory, the NU-560-600 cannot operate as a recirculating cabinet. The external exhaust blower must be properly coordinated and interlocked with the cabinet's internal blower. Facility engineering personnel should evaluate the proposed installation before purchasing or relocating the cabinet. For laboratories replacing an existing Type B2 cabinet, compatibility with the current exhaust system should be verified rather than assumed. TouchLink Electronic Control System The NuAire NU-560-600 incorporates the TouchLink electronic control system, designed to provide continuous monitoring of critical cabinet operating conditions. The touchscreen displays inflow velocity, downflow velocity, and exhaust airflow volume, giving operators access to important information about cabinet performance. The system communicates with the cabinet's airflow sensors and monitors the relationship between the internal downflow blower and the external exhaust system. TouchLink also provides alarm functions and supports protective responses to certain exhaust failures. For laboratories operating under documented quality systems, the ability to monitor and review cabinet performance can be particularly valuable. The TouchLink interface includes performance-history capabilities, with recent operating data available on-screen and additional historical information available through USB export. These features can support equipment monitoring, maintenance records, and quality-assurance procedures. Redundant Exhaust Failure Protection Loss of facility exhaust is one of the most important operating risks associated with a Class II Type B2 biosafety cabinet. If the external exhaust system fails while the cabinet's internal supply blower continues operating, protective airflow conditions may be compromised. The NU-560-600 incorporates redundant exhaust monitoring and protective interlocks designed to address this risk. A digital differential-pressure exhaust flow grid monitors exhaust performance and communicates with the TouchLink controller. A separate mechanical pressure switch provides an additional level of protection. The cabinet's control system is designed to shut down the internal downflow blower when an exhaust failure is detected, reducing the possibility of air being forced outward through the front opening. These protective systems must be maintained and verified as part of routine service and field certification. Digital Exhaust Flow Grid & Downflow Monitoring The NU-560-600 incorporates a digital exhaust flow grid that monitors exhaust airflow through differential-pressure measurement. The TouchLink system uses this information to display exhaust volume and derive relevant inflow information. A separate downflow sensor monitors the velocity of clean air moving through the work chamber. Together, these monitoring systems provide important information about the cabinet's protective airflow. For pharmaceutical research, biotechnology, and other demanding laboratory applications, continuous airflow monitoring can help operators identify operating problems before they affect laboratory procedures. These systems complement, but do not replace, independent field certification. Energy-Efficient DC Motor The NuAire LabGard ES TE NU-560-600 incorporates a DC electronically commutated motor designed to provide efficient and dependable downflow airflow. The motor supplies HEPA-filtered air to the work chamber and compensates for increasing resistance as the supply HEPA filter accumulates particulate material. The motor's efficiency is particularly valuable in a large 6-foot cabinet where substantial airflow must be maintained. However, total exhaust cabinets also impose significant demands on building ventilation systems. Overall operating costs should therefore account for the dedicated exhaust blower, conditioned replacement air, heating, cooling, and ongoing certification requirements. For laboratories considering a refurbished Type B2 cabinet, evaluating these facility-related costs is an important part of equipment selection. HEPA Filtration & HEPEX Filter-Sealing System The NU-560-600 incorporates separate supply and exhaust HEPA filters designed to provide 99.99% filtration efficiency at 0.3 microns. The supply HEPA filter provides clean vertical downflow air within the work chamber. The exhaust HEPA filter removes airborne particles from cabinet exhaust before the air enters the facility exhaust system. NuAire's HEPEX filter-sealing system uses spring-loaded sealing components designed to maintain secure filter installation and simplify servicing. The cabinet incorporates a 3-inch supply HEPA filter and an approximately 11.5-inch exhaust HEPA filter in the standard configuration. Proper filter installation, integrity testing, and certification are essential to maintaining the cabinet's intended containment performance. Because HEPA filters do not remove chemical vapors, the external exhaust system remains essential when handling permitted volatile chemical substances. Stainless Steel Construction & Cleaning The NU-560-600 incorporates welded Type 304 stainless steel construction designed for durability, containment, and routine laboratory cleaning. The work chamber uses a single-piece stainless steel arrangement along the side and rear walls, minimizing seams and supporting cleanability. The cabinet also incorporates a one-piece dished stainless steel work tray designed to contain minor spills. A prop rod allows the tray to be raised for access to areas beneath the working surface. These features are especially useful in pharmaceutical research, biotechnology, and biological laboratories where cleaning and decontamination are performed frequently. The cabinet also incorporates a front-right drain valve and provisions for laboratory service connections. Cleaning and decontamination procedures should be selected according to the biological agents, chemicals, and materials handled within the cabinet. Large 6-Foot Work Chamber The NuAire NU-560-600 provides approximately 70.4 inches of interior width, 26 inches of depth, and 25.2 inches of height. This spacious work chamber accommodates multiple sample racks, culture vessels, reagent containers, and compatible laboratory instruments. The additional width can be particularly valuable for specialized procedures requiring several work zones or multiple pieces of equipment inside the cabinet. Researchers should organize materials to avoid obstructing the front intake grille, rear airflow openings, or intended downflow pattern. The cabinet's 8-inch working sash opening must be maintained during normal biological procedures. NU-560-600 vs. NU-540-600: Type B2 vs. Type A2 The NuAire NU-560-600 and NU-540-600 are both nominal 6-foot Class II biological safety cabinets, but their airflow designs and installation requirements differ substantially. The NU-560-600 is a Class II Type B2 total exhaust cabinet that directs 100% of its airflow through an external exhaust system. The NU-540-600 is a Class II Type A2 cabinet that recirculates most of its airflow internally and can generally operate without direct facility exhaust for appropriate biological applications. The NU-560-600 is intended for laboratories requiring total exhaust containment, including certain procedures involving biological materials and permitted quantities of volatile chemicals or radionuclides. The NU-540-600 is generally more practical for routine cell culture, microbiology, and other biological procedures that do not require total exhaust. Selecting between these cabinets requires evaluating the laboratory's intended applications, biological risk assessment, chemical use, ventilation infrastructure, and operating costs. Common Applications The NuAire NU-560-600 is designed for specialized laboratory procedures requiring Class II Type B2 containment. Applications may include pharmaceutical research, biotechnology, drug preparation, microbiology, cell culture, vaccine research, and certain procedures involving biological materials combined with limited quantities of volatile chemicals or radionuclides. The cabinet may also be appropriate for certain specialized pharmaceutical preparation and research workflows where complete external exhaust is required. Use with hazardous chemicals or radionuclides must be evaluated through an appropriate risk assessment, including chemical compatibility, quantities, fire hazards, exhaust-system design, and applicable safety requirements. The NU-560-600 should not automatically be treated as a substitute for a chemical fume hood for all chemical applications. Ideal Laboratory Environments The NU-560-600 is particularly well suited to pharmaceutical research facilities, biotechnology companies, specialized biological research laboratories, vaccine-development facilities, and institutions requiring externally exhausted biological containment. It is also appropriate for laboratories replacing an existing Type B2 cabinet where the necessary facility exhaust infrastructure is already installed. Because the cabinet requires a dedicated external exhaust system, it is generally less suitable for laboratories without appropriate building ventilation capabilities. Key Specifications Specification Details Manufacturer NuAire Model NU-560-600 Series LabGard ES TE Energy Saver Cabinet Classification Class II Type B2 Exhaust Configuration 100% Total Exhaust Internal Air Recirculation None Nominal Width 6 ft / 1.8 m Exterior Dimensions 77.625" W × 32.375" D × 62" H Interior Work Area 70.375" W × 26" D × 25.188" H Usable Work Tray 69.875" W × 20.875" D Working Sash Opening 8" Viewing Window Tempered Glass Cabinet Construction Welded Type 304 Stainless Steel Work Surface One-Piece Dished Stainless Steel Tray Inflow Velocity Nominal 105 FPM Downflow Velocity Nominal 60 FPM Clean-Air Classification ISO Class 5 Supply Filtration HEPA, 99.99% at 0.3 Microns Exhaust Filtration HEPA, 99.99% at 0.3 Microns Filter-Sealing System HEPEX Internal Motor DC Electronically Commutated Motor Control System TouchLink Exhaust Monitoring Digital Differential-Pressure Flow Grid Downflow Monitoring Dedicated Downflow Sensor Exhaust Failure Protection Electronic Interlock and Mechanical Pressure Switch External Exhaust Requirement Approximately 1,275 CFM Published Facility Static Pressure 1.8" Water Gauge Electrical 115V, 60 Hz Standard NU-560-600 Configuration Rated Electrical Current 10 A Lighting LED Utility Pass-Through Right Side Data Connections USB and RS-232 Net Cabinet Weight Approximately 680 lb Estimated Shipping Weight Approximately 730 lb Stand Confirm Included Configuration Exhaust Blower Facility-Supplied, Not Assumed Included HEPA Filters New Filters Unless Otherwise Specified Warranty 90 Days from American Instrument Exchange Specifications reflect NuAire manufacturer information for the NU-560-600. Actual electrical configuration, stand, installed accessories, filtration, control-system revision, and facility exhaust compatibility should be confirmed for the individual refurbished unit. Refurbishment & Testing American Instrument Exchange specializes in professionally refurbished laboratory equipment, including Class II Type A2 and Type B2 biosafety cabinets. The NuAire NU-560-600 undergoes inspection, cleaning, refurbishment, and functional testing prior to shipment. The refurbishment process includes evaluation of the internal blower, TouchLink control system, downflow sensor, exhaust monitoring components, electrical systems, sash mechanism, lighting, alarms, and filtration assemblies. Particular attention is given to the exhaust failure protection systems because safe Type B2 operation depends on proper coordination between the cabinet and the facility exhaust system. Unless otherwise specified, new HEPA filters are installed during refurbishment. The cabinet is prepared for installation and subsequent field certification at the customer's facility. Because the NU-560-600 requires an external exhaust blower, complete operating performance must be verified after the cabinet is connected to a properly engineered facility exhaust system. A 90-day warranty is included from American Instrument Exchange. Certification Readiness The NuAire NU-560-600 must be field certified after installation and before being placed into biological service. Certification should evaluate inflow and downflow velocities, HEPA filter integrity, airflow patterns, exhaust performance, alarms, and applicable safety interlocks. For a Type B2 cabinet, verification of the facility exhaust connection and exhaust failure response is particularly important. The cabinet should also be recertified at appropriate intervals and following relocation, HEPA filter replacement, significant repairs, or changes to the facility exhaust system. For laboratories throughout Greater Boston and New England, AIE Laboratory Services provides biosafety cabinet certification, preventative maintenance, HEPA filter replacement, troubleshooting, repair, and related field services. Shipping & Installation The NuAire NU-560-600 requires careful planning before delivery and installation. The cabinet measures approximately 77.6 inches wide, 32.4 inches deep, and 62 inches high, excluding any additional stand height. The cabinet weighs approximately 680 lb before packaging and accessories. Doorway clearances, loading areas, elevators, laboratory access routes, electrical requirements, and the final installation location should be evaluated before shipment. Most importantly, the receiving facility must have a dedicated exhaust system capable of supporting the cabinet's published airflow requirements. The external exhaust blower, ductwork, building pressure conditions, and interlock connections must be evaluated and coordinated by qualified personnel. American Instrument Exchange can assist with freight coordination and equipment placement planning. Following installation and connection to the facility exhaust system, the cabinet must be field certified before biological use. Related Laboratory Equipment The NuAire NU-560-600 is particularly useful in specialized pharmaceutical, biotechnology, microbiology, and biological research workflows. For cell culture applications, the cabinet can be paired with CO₂ incubators, refrigerated centrifuges, laboratory refrigerators, and ultra-low temperature freezers. Laboratory autoclaves support sterilization workflows, while additional biosafety cabinets can provide appropriate containment for other laboratory procedures. American Instrument Exchange maintains a broad inventory of professionally refurbished laboratory equipment, allowing laboratories to source multiple compatible instruments through a single supplier. NuAire NU-560-600 Frequently Asked Questions What type of biosafety cabinet is the NuAire NU-560-600? The NU-560-600 is a 6-foot Class II Type B2 total exhaust biosafety cabinet. It is designed to provide personnel, product, and environmental protection when properly installed, operated, and certified. Does the NuAire NU-560-600 recirculate air? No. The NU-560-600 uses a 100% total exhaust configuration. Air entering the cabinet is discharged through HEPA filtration and a dedicated external facility exhaust system rather than being recirculated within the cabinet. Does the NU-560-600 require external exhaust? Yes. The cabinet requires a properly engineered external exhaust system. The manufacturer's published requirement for the 6-foot model is approximately 1,275 CFM at 1.8 inches water gauge static pressure. Actual installation requirements must be evaluated by qualified facility personnel. Is an external exhaust blower included? The NU-560-600 is designed to operate with a facility-supplied external exhaust blower. An external blower should not be assumed to be included with a refurbished cabinet unless specifically identified in the equipment listing or quotation. Can the NU-560-600 operate without facility exhaust? No. A Class II Type B2 cabinet depends on the external exhaust system for proper operation and containment. The NU-560-600 should not be operated as a recirculating biosafety cabinet. What is the difference between the NU-560-600 and NU-540-600? The NU-560-600 is a Class II Type B2 total exhaust cabinet, while the NU-540-600 is a Class II Type A2 cabinet. The NU-560-600 exhausts 100% of its airflow externally, whereas the NU-540-600 recirculates most of its airflow internally. The correct model depends on the laboratory's applications and ventilation requirements. Can the NU-560-600 be used with volatile chemicals? The NU-560-600 may be appropriate for certain procedures involving biological materials and limited quantities of volatile chemicals, subject to a documented risk assessment and suitable exhaust design. The cabinet is not automatically appropriate for all hazardous chemicals, flammable substances, or chemical processes. HEPA filters do not remove chemical vapors. What is the TouchLink control system? TouchLink is NuAire's electronic control and monitoring system. It displays important airflow information, including inflow velocity, downflow velocity, and exhaust volume. The system also monitors operating conditions and supports protective responses to exhaust failure. What happens if the external exhaust blower fails? The NU-560 incorporates electronic exhaust monitoring and a separate mechanical pressure switch. These systems are designed to detect loss of exhaust and shut down the internal downflow blower to reduce the risk of compromised containment. The cabinet should not be used until the exhaust problem has been corrected and safe operation verified. Does the NU-560-600 have HEPA filtration? Yes. The cabinet incorporates separate supply and exhaust HEPA filters. Both are designed to provide 99.99% filtration efficiency at 0.3 microns. The supply filter provides clean downflow air, while the exhaust filter removes airborne particles before air enters the facility exhaust system. Does the NuAire NU-560-600 include a stand? The NU-560 platform can be configured with compatible base stands. The exact stand configuration included with a refurbished NU-560-600 should be confirmed before purchase. Does the NU-560-600 need certification after installation? Yes. The cabinet must be field certified after installation and connection to the facility exhaust system. Certification should verify airflow, HEPA filter integrity, exhaust performance, and relevant safety interlocks before biological use. Can AIE Laboratory Services certify or repair a NuAire NU-560? Yes. AIE Laboratory Services provides biosafety cabinet certification, preventative maintenance, HEPA filter replacement, troubleshooting, and repair services throughout Greater Boston and New England. Service availability and the scope of work should be coordinated based on the cabinet's installation and facility exhaust requirements. Is an older NuAire NU-560 worth repairing? In many cases, yes. A Type B2 cabinet represents a substantial equipment and facility investment. Replacement may involve not only the cost of a new cabinet but also exhaust-system modifications, installation, and certification. Problems involving controls, sensors, filtration, alarms, or serviceable electrical components do not automatically require replacement of the entire cabinet. Repair feasibility depends on cabinet condition, parts availability, and the ability to restore and certify proper performance. Why purchase a refurbished NuAire NU-560-600 from American Instrument Exchange? The NuAire NU-560-600 combines a large 6-foot stainless steel work chamber with Class II Type B2 total exhaust containment, TouchLink controls, redundant exhaust failure protection, and energy-efficient motor technology. American Instrument Exchange specializes in professionally refurbished laboratory equipment, providing laboratories with cost-effective alternatives to purchasing new instruments. Each refurbished cabinet is inspected, cleaned, and functionally tested prior to shipment, with new HEPA filters installed unless otherwise specified and a 90-day warranty included. For laboratories requiring a 6-foot Class II Type B2 total exhaust biosafety cabinet, the refurbished NuAire NU-560-600 offers an excellent combination of containment technology, working space, and value.
Variants (1)
- Default Title — 7400.00 USD — Out of stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.