VinScreen 6-panel + Alc Urine Drug Test
Six-panel urine drug test cup with a built-in alcohol strip, adulteration and specimen validity checks. Complete on-site drug + alcohol screening from a single sample. Drug panels independently verified by RASL to AS/NZS 4308:2023 — the current Australian Standard for urine drug screening. If a drug result is ever challenged, you can show the device was tested against it. Why choose VinScreen 6-Panel + ALC Drugs and alcohol in one cup — integrated cup with six drug panels plus an alcohol test strip. One collection, one device. Verified to the current standard — drug panels independently verified by RASL to AS/NZS 4308:2023, including the revised 150 ng/mL cocaine cut-off. All-in-one cup — collection, drug screening, alcohol screening and specimen validity testing in a single sealed device. No decanting, no separate strips. Six validity checks built in — pH, specific gravity, oxidants, creatinine, nitrite and glutaraldehyde, read directly off the cup. External temperature strip — catches substituted samples, which chemical checks alone will not detect. Five-minute read — drug results at five minutes, stable for up to 60 minutes, so a collector can process several donors without losing a result. Matched against laboratory methods — 94.3% to 100% agreement with GC/MS across all six drug panels in manufacturer testing. Tested for interference — no interference on the drug panels from more than 40 common substances including caffeine, ibuprofen, paracetamol, aspirin and ethanol at 100 µg/mL. Detected panels (6-Panel) + Alcohol Drug class Abbrev. Calibrator Cut-off Amphetamine AMP D-Amphetamine 300 ng/mL Methamphetamine MET D-Methamphetamine 300 ng/mL Cocaine COC Benzoylecgonine 150 ng/mL Opiates OPI Morphine 300 ng/mL Benzodiazepines BZO Oxazepam 200 ng/mL Cannabis THC 11-nor-Δ9-THC-9-COOH 50 ng/mL Alcohol (urine screen) ALC Ethanol Preset ranges The alcohol strip indicates preset ranges in urine. For exact BAC%, use a calibrated breathalyser per your policy. Specimen validity and integrity checks A donor attempting to defeat a urine screen has three options: substitute someone else's sample or a synthetic one, dilute their own, or add a masking agent. This cup checks for all three. Substitution is caught by the external temperature strip — read it immediately after collection. A sample outside the expected range did not come from the donor in front of you. No chemical check will tell you this. Dilution and adulteration are caught by the six reagent pads below, read against the supplied colour chart at three to five minutes. Check Normal range What it identifies pH 4 – 9 Acid or alkaline adulteration Specific gravity 1.003 – 1.030 Dilution or substitution Oxidants / PCC None present Bleach, peroxide, pyridinium chlorochromate Creatinine 20 – 300 mg/dL Dilution Nitrite Below 15 mg/dL Nitrite-based masking agents Glutaraldehyde None present Commercial masking products How to use Allow the device to reach room temperature (15–30°C). Do not open the pouch until you are ready to test. Remove the cup from the sealed pouch and write the donor name or ID in the space provided. Collect the urine sample directly in the cup. Read the temperature strip immediately — within four minutes of collection, per standard collection practice. Read the adulteration pads against the colour chart at three to five minutes. Read the alcohol strip against the colour chart within the time window given in the Instructions for Use. Read the drug results at five minutes. Results remain stable for 60 minutes. Always follow the Instructions for Use supplied with the kit. How to interpret results Drug panels: a visible test line means negative. This is the opposite of what people often expect. Negative — a red or pink line appears next to T1 or T2 under the drug name. Faint or thin lines still count as negative. Preliminary positive — no line appears next to T1 or T2 for that drug. Send the sample for laboratory confirmation. Invalid — no line next to C on one or more strips. Discard and retest with a new device. Alcohol strip: compare the alcohol pad against the colour chart to see which preset range the sample falls into. For exact BAC%, follow up with a calibrated breathalyser per your policy. Do not read results after 60 minutes. Screening results are preliminary. Any non-negative result should be confirmed in accordance with your workplace policy. What's included VinScreen 6-Panel + ALC urine test cup with integrated alcohol strip, adulteration strip and external temperature strip Colour comparison chart Instructions for Use Best for Workplace drug and alcohol screening Pre-employment, random, post-incident and fitness-for-duty testing Mining, construction and heavy industry Transport, logistics and agriculture Drug testing service providers and accredited collectors Buying for a workplace? Corporate pricing, 14-day accounts and purchase orders are available. Request a quote — we respond within 4 business hours. Need to talk it through first? Contact us and we'll help you work out which device fits your drug and alcohol testing programme.
Specifications
- Packs
- 25 Kits, 100 Kits, 250 Kits, 500 Kits
Variants (4)
- 25 Kits — 12.50 AUD — In stock
- 100 Kits — 11.50 AUD — In stock
- 250 Kits — 11.00 AUD — In stock
- 500 Kits — 10.50 AUD — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.