Easesyn ES50B-VET Veterinary Patient Monitor ICU CCU Vital Signs Monitor 6 Parameters
Performance ▲ECG Lead mode:3-lead or 5-lead Lead selection:I, II, III, aVR, aVL, aVF, V Waveform:5-lead, 2-channel 3-lead, 1-channel Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed:12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range:15~350bpm Accuracy:±1% or ±1bpm, whichever is greater Alarm accuracy:± 2 bpm Resolution:1 bpm ST-segment monitoring: Measurement and alarm range: -2.0mV~+2.0mV Accuracy:-0.8mV~+0.8mV ±0.04mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker:yes ▲RESPIRATION Method:R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range:0~150rpm Resolution:1 rpm Measurement accuracy:±2 rpm Alarm accuracy:±3 rpm Apnea alarm:10~40s Scan speed:6.25 mm/s, 12.5 mm/s, 25 mm/s ▲NIBP Method:Oscillometry Mode:Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in STAT mode:5 minutes Measurement and alarm range:10 ~ 270 mmHg Resolution:1 mmHg Cuff pressure accuracy:±3 mmHg Measurement accuracy: Maximal mean error:±5 mmHg Maximal standard deviation:8mmHg Over-pressure protection: Other mode:297±3 mmHg Dog mode:240±3 mmHg Cat mode: 147±3 mmHg ▲SpO2 Measurement and alarm range:0 ~ 100% Resolution:1% Measurement accuracy:70%~100%: ±2%; 0%~69%: unspecified ▲PR Measurement and alarm range:30 ~ 250 bpm Measurement accuracy:±2 bpm or ±2%, whichever is greater ▲TEMP Channel:dual-channel Measurement and alarm range:0 ~ 50℃ Resolution:0.1 ℃ Accuracy:±0.1 ℃ ▲Power supply:100-240V~,50/60Hz ▲Safety classification:Class I, type CF defibrillation-proof applied part Accessories 1)Digital BD7 veterinary tongue-clip SpO2 sensor (1M) 2)General digital SpO2 sensor extension cable (2M) 3)Neonatal capsule single tube repeatable cuff (6-11cm) 4)NIBP extension tube 5)5-lead ECG lead cable (American-Standard) 6)ECG veterinary clip (*5) 7)Transvaginal TEMP probe 8)Power adapter 9)Power cord 10)User Manual 11)ETCO2 Module+sampling tube (optional) Physical characteristic Dimension: 235 mm(L) × 141 mm(W) × 222 mm(H) Weight: 2.5 Kg
Specifications
- 样式
- ES50B-VET, ES50B-VET+ETCO2
Variants (2)
- ES50B-VET — 599.00 USD — In stock
- ES50B-VET+ETCO2 — 818.00 USD — In stock
How AI sees this product
The more complete this product's details, the more confidently AI assistants can understand and recommend it.